001/* 002 * Copyright (C) Cross The Road Electronics. All rights reserved. 003 * License information can be found in CTRE_LICENSE.txt 004 * For support and suggestions contact support@ctr-electronics.com or file 005 * an issue tracker at https://github.com/CrossTheRoadElec/Phoenix-Releases 006 */ 007package com.ctre.phoenix6.configs; 008 009import com.ctre.phoenix6.StatusCode; 010import com.ctre.phoenix6.configs.jni.ConfigJNI; 011import com.ctre.phoenix6.spns.*; 012import com.ctre.phoenix6.signals.*; 013 014/** 015 * Gains for the specified slot. 016 * <p> 017 * If this slot is selected, these gains are used in closed loop 018 * control requests. 019 */ 020public class Slot1Configs implements ParentConfiguration 021{ 022 /** 023 * Proportional Gain. 024 * <p> 025 * The units for this gain is dependent on the control mode. Since 026 * this gain is multiplied by error in the input, the units should be 027 * defined as units of output per unit of input error. For example, 028 * when controlling velocity using a duty cycle closed loop, the units 029 * for the proportional gain will be duty cycle per rps, or 1/rps. 030 * 031 * <ul> 032 * <li> <b>Minimum Value:</b> 0 033 * <li> <b>Maximum Value:</b> 3.4e+38 034 * <li> <b>Default Value:</b> 0 035 * <li> <b>Units:</b> 036 * </ul> 037 */ 038 public double kP = 0; 039 /** 040 * Integral Gain. 041 * <p> 042 * The units for this gain is dependent on the control mode. Since 043 * this gain is multiplied by error in the input integrated over time 044 * (in units of seconds), the units should be defined as units of 045 * output per unit of integrated input error. For example, when 046 * controlling velocity using a duty cycle closed loop, integrating 047 * velocity over time results in rps * s = rotations. Therefore, the 048 * units for the integral gain will be duty cycle per rotation of 049 * accumulated error, or 1/rot. 050 * 051 * <ul> 052 * <li> <b>Minimum Value:</b> 0 053 * <li> <b>Maximum Value:</b> 3.4e+38 054 * <li> <b>Default Value:</b> 0 055 * <li> <b>Units:</b> 056 * </ul> 057 */ 058 public double kI = 0; 059 /** 060 * Derivative Gain. 061 * <p> 062 * The units for this gain is dependent on the control mode. Since 063 * this gain is multiplied by the derivative of error in the input 064 * with respect to time (in units of seconds), the units should be 065 * defined as units of output per unit of the differentiated input 066 * error. For example, when controlling velocity using a duty cycle 067 * closed loop, the derivative of velocity with respect to time is rot 068 * per sec², which is acceleration. Therefore, the units for the 069 * derivative gain will be duty cycle per unit of acceleration error, 070 * or 1/(rot per sec²). 071 * 072 * <ul> 073 * <li> <b>Minimum Value:</b> 0 074 * <li> <b>Maximum Value:</b> 3.4e+38 075 * <li> <b>Default Value:</b> 0 076 * <li> <b>Units:</b> 077 * </ul> 078 */ 079 public double kD = 0; 080 /** 081 * Static Feedforward Gain. 082 * <p> 083 * This is added to the closed loop output. The unit for this constant 084 * is dependent on the control mode, typically fractional duty cycle, 085 * voltage, or torque current. 086 * <p> 087 * The sign is typically determined by reference velocity when using 088 * position, velocity, and Motion Magic® closed loop modes. However, 089 * when using position closed loop with zero velocity reference (no 090 * motion profiling), the application can instead use the position 091 * closed loop error by setting the Static Feedforward Sign 092 * configuration parameter. When doing so, we recommend the minimal 093 * amount of kS, otherwise the motor output may dither when closed 094 * loop error is near zero. 095 * 096 * <ul> 097 * <li> <b>Minimum Value:</b> -512 098 * <li> <b>Maximum Value:</b> 511 099 * <li> <b>Default Value:</b> 0 100 * <li> <b>Units:</b> 101 * </ul> 102 */ 103 public double kS = 0; 104 /** 105 * Velocity Feedforward Gain. 106 * <p> 107 * The units for this gain is dependent on the control mode. Since 108 * this gain is multiplied by the requested velocity, the units should 109 * be defined as units of output per unit of requested input velocity. 110 * For example, when controlling velocity using a duty cycle closed 111 * loop, the units for the velocity feedfoward gain will be duty cycle 112 * per requested rps, or 1/rps. 113 * 114 * <ul> 115 * <li> <b>Minimum Value:</b> 0 116 * <li> <b>Maximum Value:</b> 3.4e+38 117 * <li> <b>Default Value:</b> 0 118 * <li> <b>Units:</b> 119 * </ul> 120 */ 121 public double kV = 0; 122 /** 123 * Acceleration Feedforward Gain. 124 * <p> 125 * The units for this gain is dependent on the control mode. Since 126 * this gain is multiplied by the requested acceleration, the units 127 * should be defined as units of output per unit of requested input 128 * acceleration. For example, when controlling velocity using a duty 129 * cycle closed loop, the units for the acceleration feedfoward gain 130 * will be duty cycle per requested rot per sec², or 1/(rot per sec²). 131 * 132 * <ul> 133 * <li> <b>Minimum Value:</b> 0 134 * <li> <b>Maximum Value:</b> 3.4e+38 135 * <li> <b>Default Value:</b> 0 136 * <li> <b>Units:</b> 137 * </ul> 138 */ 139 public double kA = 0; 140 /** 141 * Gravity Feedforward/Feedback Gain. 142 * <p> 143 * This is added to the closed loop output. The sign is determined by 144 * GravityType. The unit for this constant is dependent on the control 145 * mode, typically fractional duty cycle, voltage, or torque current. 146 * 147 * <ul> 148 * <li> <b>Minimum Value:</b> -512 149 * <li> <b>Maximum Value:</b> 511 150 * <li> <b>Default Value:</b> 0 151 * <li> <b>Units:</b> 152 * </ul> 153 */ 154 public double kG = 0; 155 /** 156 * Gravity Feedforward/Feedback Type. 157 * <p> 158 * This determines the type of the gravity feedforward/feedback. 159 * <p> 160 * Choose Elevator_Static for systems where the gravity feedforward is 161 * constant, such as an elevator. The gravity feedforward output will 162 * always be positive. 163 * <p> 164 * Choose Arm_Cosine for systems where the gravity feedback is 165 * dependent on the angular position of the mechanism, such as an arm. 166 * The gravity feedback output will vary depending on the mechanism 167 * angular position. Note that the sensor offset and ratios must be 168 * configured so that the sensor position is 0 when the mechanism is 169 * horizonal, and one rotation of the mechanism corresponds to one 170 * rotation of the sensor position. 171 * 172 */ 173 public GravityTypeValue GravityType = GravityTypeValue.Elevator_Static; 174 /** 175 * Static Feedforward Sign during position closed loop. 176 * <p> 177 * This determines the sign of the applied kS during position 178 * closed-loop modes. The default behavior uses the velocity reference 179 * sign. This works well with velocity closed loop, Motion Magic® 180 * controls, and position closed loop when velocity reference is 181 * specified (motion profiling). 182 * <p> 183 * However, when using position closed loop with zero velocity 184 * reference (no motion profiling), the application may want to apply 185 * static feedforward based on the closed loop error sign instead. 186 * When doing so, we recommend using the minimal amount of kS, 187 * otherwise the motor output may dither when closed loop error is 188 * near zero. 189 * 190 */ 191 public StaticFeedforwardSignValue StaticFeedforwardSign = StaticFeedforwardSignValue.UseVelocitySign; 192 193 /** 194 * Modifies this configuration's kP parameter and returns itself for 195 * method-chaining and easier to use config API. 196 * <p> 197 * Proportional Gain. 198 * <p> 199 * The units for this gain is dependent on the control mode. Since 200 * this gain is multiplied by error in the input, the units should be 201 * defined as units of output per unit of input error. For example, 202 * when controlling velocity using a duty cycle closed loop, the units 203 * for the proportional gain will be duty cycle per rps, or 1/rps. 204 * 205 * <ul> 206 * <li> <b>Minimum Value:</b> 0 207 * <li> <b>Maximum Value:</b> 3.4e+38 208 * <li> <b>Default Value:</b> 0 209 * <li> <b>Units:</b> 210 * </ul> 211 * 212 * @param newKP Parameter to modify 213 * @return Itself 214 */ 215 public Slot1Configs withKP(double newKP) 216 { 217 kP = newKP; 218 return this; 219 } 220 221 /** 222 * Modifies this configuration's kI parameter and returns itself for 223 * method-chaining and easier to use config API. 224 * <p> 225 * Integral Gain. 226 * <p> 227 * The units for this gain is dependent on the control mode. Since 228 * this gain is multiplied by error in the input integrated over time 229 * (in units of seconds), the units should be defined as units of 230 * output per unit of integrated input error. For example, when 231 * controlling velocity using a duty cycle closed loop, integrating 232 * velocity over time results in rps * s = rotations. Therefore, the 233 * units for the integral gain will be duty cycle per rotation of 234 * accumulated error, or 1/rot. 235 * 236 * <ul> 237 * <li> <b>Minimum Value:</b> 0 238 * <li> <b>Maximum Value:</b> 3.4e+38 239 * <li> <b>Default Value:</b> 0 240 * <li> <b>Units:</b> 241 * </ul> 242 * 243 * @param newKI Parameter to modify 244 * @return Itself 245 */ 246 public Slot1Configs withKI(double newKI) 247 { 248 kI = newKI; 249 return this; 250 } 251 252 /** 253 * Modifies this configuration's kD parameter and returns itself for 254 * method-chaining and easier to use config API. 255 * <p> 256 * Derivative Gain. 257 * <p> 258 * The units for this gain is dependent on the control mode. Since 259 * this gain is multiplied by the derivative of error in the input 260 * with respect to time (in units of seconds), the units should be 261 * defined as units of output per unit of the differentiated input 262 * error. For example, when controlling velocity using a duty cycle 263 * closed loop, the derivative of velocity with respect to time is rot 264 * per sec², which is acceleration. Therefore, the units for the 265 * derivative gain will be duty cycle per unit of acceleration error, 266 * or 1/(rot per sec²). 267 * 268 * <ul> 269 * <li> <b>Minimum Value:</b> 0 270 * <li> <b>Maximum Value:</b> 3.4e+38 271 * <li> <b>Default Value:</b> 0 272 * <li> <b>Units:</b> 273 * </ul> 274 * 275 * @param newKD Parameter to modify 276 * @return Itself 277 */ 278 public Slot1Configs withKD(double newKD) 279 { 280 kD = newKD; 281 return this; 282 } 283 284 /** 285 * Modifies this configuration's kS parameter and returns itself for 286 * method-chaining and easier to use config API. 287 * <p> 288 * Static Feedforward Gain. 289 * <p> 290 * This is added to the closed loop output. The unit for this constant 291 * is dependent on the control mode, typically fractional duty cycle, 292 * voltage, or torque current. 293 * <p> 294 * The sign is typically determined by reference velocity when using 295 * position, velocity, and Motion Magic® closed loop modes. However, 296 * when using position closed loop with zero velocity reference (no 297 * motion profiling), the application can instead use the position 298 * closed loop error by setting the Static Feedforward Sign 299 * configuration parameter. When doing so, we recommend the minimal 300 * amount of kS, otherwise the motor output may dither when closed 301 * loop error is near zero. 302 * 303 * <ul> 304 * <li> <b>Minimum Value:</b> -512 305 * <li> <b>Maximum Value:</b> 511 306 * <li> <b>Default Value:</b> 0 307 * <li> <b>Units:</b> 308 * </ul> 309 * 310 * @param newKS Parameter to modify 311 * @return Itself 312 */ 313 public Slot1Configs withKS(double newKS) 314 { 315 kS = newKS; 316 return this; 317 } 318 319 /** 320 * Modifies this configuration's kV parameter and returns itself for 321 * method-chaining and easier to use config API. 322 * <p> 323 * Velocity Feedforward Gain. 324 * <p> 325 * The units for this gain is dependent on the control mode. Since 326 * this gain is multiplied by the requested velocity, the units should 327 * be defined as units of output per unit of requested input velocity. 328 * For example, when controlling velocity using a duty cycle closed 329 * loop, the units for the velocity feedfoward gain will be duty cycle 330 * per requested rps, or 1/rps. 331 * 332 * <ul> 333 * <li> <b>Minimum Value:</b> 0 334 * <li> <b>Maximum Value:</b> 3.4e+38 335 * <li> <b>Default Value:</b> 0 336 * <li> <b>Units:</b> 337 * </ul> 338 * 339 * @param newKV Parameter to modify 340 * @return Itself 341 */ 342 public Slot1Configs withKV(double newKV) 343 { 344 kV = newKV; 345 return this; 346 } 347 348 /** 349 * Modifies this configuration's kA parameter and returns itself for 350 * method-chaining and easier to use config API. 351 * <p> 352 * Acceleration Feedforward Gain. 353 * <p> 354 * The units for this gain is dependent on the control mode. Since 355 * this gain is multiplied by the requested acceleration, the units 356 * should be defined as units of output per unit of requested input 357 * acceleration. For example, when controlling velocity using a duty 358 * cycle closed loop, the units for the acceleration feedfoward gain 359 * will be duty cycle per requested rot per sec², or 1/(rot per sec²). 360 * 361 * <ul> 362 * <li> <b>Minimum Value:</b> 0 363 * <li> <b>Maximum Value:</b> 3.4e+38 364 * <li> <b>Default Value:</b> 0 365 * <li> <b>Units:</b> 366 * </ul> 367 * 368 * @param newKA Parameter to modify 369 * @return Itself 370 */ 371 public Slot1Configs withKA(double newKA) 372 { 373 kA = newKA; 374 return this; 375 } 376 377 /** 378 * Modifies this configuration's kG parameter and returns itself for 379 * method-chaining and easier to use config API. 380 * <p> 381 * Gravity Feedforward/Feedback Gain. 382 * <p> 383 * This is added to the closed loop output. The sign is determined by 384 * GravityType. The unit for this constant is dependent on the control 385 * mode, typically fractional duty cycle, voltage, or torque current. 386 * 387 * <ul> 388 * <li> <b>Minimum Value:</b> -512 389 * <li> <b>Maximum Value:</b> 511 390 * <li> <b>Default Value:</b> 0 391 * <li> <b>Units:</b> 392 * </ul> 393 * 394 * @param newKG Parameter to modify 395 * @return Itself 396 */ 397 public Slot1Configs withKG(double newKG) 398 { 399 kG = newKG; 400 return this; 401 } 402 403 /** 404 * Modifies this configuration's GravityType parameter and returns itself for 405 * method-chaining and easier to use config API. 406 * <p> 407 * Gravity Feedforward/Feedback Type. 408 * <p> 409 * This determines the type of the gravity feedforward/feedback. 410 * <p> 411 * Choose Elevator_Static for systems where the gravity feedforward is 412 * constant, such as an elevator. The gravity feedforward output will 413 * always be positive. 414 * <p> 415 * Choose Arm_Cosine for systems where the gravity feedback is 416 * dependent on the angular position of the mechanism, such as an arm. 417 * The gravity feedback output will vary depending on the mechanism 418 * angular position. Note that the sensor offset and ratios must be 419 * configured so that the sensor position is 0 when the mechanism is 420 * horizonal, and one rotation of the mechanism corresponds to one 421 * rotation of the sensor position. 422 * 423 * 424 * @param newGravityType Parameter to modify 425 * @return Itself 426 */ 427 public Slot1Configs withGravityType(GravityTypeValue newGravityType) 428 { 429 GravityType = newGravityType; 430 return this; 431 } 432 433 /** 434 * Modifies this configuration's StaticFeedforwardSign parameter and returns itself for 435 * method-chaining and easier to use config API. 436 * <p> 437 * Static Feedforward Sign during position closed loop. 438 * <p> 439 * This determines the sign of the applied kS during position 440 * closed-loop modes. The default behavior uses the velocity reference 441 * sign. This works well with velocity closed loop, Motion Magic® 442 * controls, and position closed loop when velocity reference is 443 * specified (motion profiling). 444 * <p> 445 * However, when using position closed loop with zero velocity 446 * reference (no motion profiling), the application may want to apply 447 * static feedforward based on the closed loop error sign instead. 448 * When doing so, we recommend using the minimal amount of kS, 449 * otherwise the motor output may dither when closed loop error is 450 * near zero. 451 * 452 * 453 * @param newStaticFeedforwardSign Parameter to modify 454 * @return Itself 455 */ 456 public Slot1Configs withStaticFeedforwardSign(StaticFeedforwardSignValue newStaticFeedforwardSign) 457 { 458 StaticFeedforwardSign = newStaticFeedforwardSign; 459 return this; 460 } 461 462 public static Slot1Configs from(SlotConfigs value) 463 { 464 return new Slot1Configs() {{ 465 kP = value.kP; 466 kI = value.kI; 467 kD = value.kD; 468 kS = value.kS; 469 kV = value.kV; 470 kA = value.kA; 471 kG = value.kG; 472 GravityType = value.GravityType; 473 StaticFeedforwardSign = value.StaticFeedforwardSign; 474 }}; 475 } 476 477 @Override 478 public String toString() 479 { 480 String ss = "Config Group: Slot1\n"; 481 ss += " kP: " + kP + "\n"; 482 ss += " kI: " + kI + "\n"; 483 ss += " kD: " + kD + "\n"; 484 ss += " kS: " + kS + "\n"; 485 ss += " kV: " + kV + "\n"; 486 ss += " kA: " + kA + "\n"; 487 ss += " kG: " + kG + "\n"; 488 ss += " GravityType: " + GravityType + "\n"; 489 ss += " StaticFeedforwardSign: " + StaticFeedforwardSign + "\n"; 490 return ss; 491 } 492 493 /** 494 * 495 */ 496 public StatusCode deserialize(String to_deserialize) 497 { 498 kP = ConfigJNI.Deserializedouble(SpnValue.Slot1_kP.value, to_deserialize); 499 kI = ConfigJNI.Deserializedouble(SpnValue.Slot1_kI.value, to_deserialize); 500 kD = ConfigJNI.Deserializedouble(SpnValue.Slot1_kD.value, to_deserialize); 501 kS = ConfigJNI.Deserializedouble(SpnValue.Slot1_kS.value, to_deserialize); 502 kV = ConfigJNI.Deserializedouble(SpnValue.Slot1_kV.value, to_deserialize); 503 kA = ConfigJNI.Deserializedouble(SpnValue.Slot1_kA.value, to_deserialize); 504 kG = ConfigJNI.Deserializedouble(SpnValue.Slot1_kG.value, to_deserialize); 505 GravityType = GravityTypeValue.valueOf(ConfigJNI.Deserializeint(SpnValue.Slot1_kG_Type.value, to_deserialize)); 506 StaticFeedforwardSign = StaticFeedforwardSignValue.valueOf(ConfigJNI.Deserializeint(SpnValue.Slot1_kS_Sign.value, to_deserialize)); 507 return StatusCode.OK; 508 } 509 510 /** 511 * 512 */ 513 public String serialize() 514 { 515 String ss = ""; 516 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kP.value, kP); 517 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kI.value, kI); 518 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kD.value, kD); 519 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kS.value, kS); 520 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kV.value, kV); 521 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kA.value, kA); 522 ss += ConfigJNI.Serializedouble(SpnValue.Slot1_kG.value, kG); 523 ss += ConfigJNI.Serializeint(SpnValue.Slot1_kG_Type.value, GravityType.value); 524 ss += ConfigJNI.Serializeint(SpnValue.Slot1_kS_Sign.value, StaticFeedforwardSign.value); 525 return ss; 526 } 527} 528