DifferentialDutyCycle Class

Request a specified motor duty cycle with a differential position closed-loop.

This control mode will output a proportion of the supplied voltage which is supplied by the user. It will also set the motor's differential position setpoint to the specified position.

Definition

Namespace: CTRE.Phoenix6.Controls
Assembly: Phoenix6 (in Phoenix6.dll) Version: 1.0.0
C#
public class DifferentialDutyCycle : ControlRequest
Inheritance
Object    ControlRequest    DifferentialDutyCycle

Constructors

DifferentialDutyCycle Request a specified motor duty cycle with a differential position closed-loop.

This control mode will output a proportion of the supplied voltage which is supplied by the user. It will also set the motor's differential position setpoint to the specified position. TargetOutput Proportion of supply voltage to apply in fractional units between -1 and +1 DifferentialPosition Differential position to drive towards in rotations EnableFOC Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation. FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains. DifferentialSlot Select which gains are applied to the differential controller by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2]. OverrideBrakeDurNeutral Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.

Properties

ConfigTimeout The timeout when sending configs associated with this control
ControlInfo Plain old data container holding name-value pairs of the control request parameters
(Inherited from ControlRequest)
DifferentialPosition Differential position to drive towards in rotations
DifferentialSlot Select which gains are applied to the differential controller by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2].
EnableFOC Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation. FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.
OverrideBrakeDurNeutral Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.
TargetOutput Proportion of supply voltage to apply in fractional units between -1 and +1
UpdateFreqHz The period at which this control will update at. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms).

If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

Methods

EqualsDetermines whether the specified object is equal to the current object.
(Inherited from Object)
FinalizeAllows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)
ForceApplyConfigs Forces configs to be applied the next time this is used in a setControl.

This is not necessary in the majority of cases, because Phoenix will make sure configs are properly set when they are not already set

GetHashCodeServes as the default hash function.
(Inherited from Object)
GetTypeGets the Type of the current instance.
(Inherited from Object)
MemberwiseCloneCreates a shallow copy of the current Object.
(Inherited from Object)
SendRequest Sends this request out over CAN bus to the device for the device to apply.
(Overrides ControlRequestSendRequest(String, UInt32, Boolean))
ToString Provides the string representation of this object
(Overrides ObjectToString)
WithUpdateFreqHz Sets the period at which this control will update at. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms).

If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.