Class DifferentialFollower
- All Implemented Interfaces:
ControlRequest,Cloneable
If Talon is in torque control, the differential torque is copied - which will increase the total torque applied. If Talon is in duty cycle output control, the differential duty cycle is matched. If Talon is in voltage output control, the differential motor voltage is matched. Motor direction either matches leader's configured direction or opposes it based on the MotorAlignment.
The leader must enable its DifferentialOutput status signal. The update rate of the status signal determines the update rate of the follower's output and should be no slower than 20 Hz.
-
Field Summary
FieldsModifier and TypeFieldDescriptionintDevice ID of the differential leader to follow.Set to Aligned for motor invert to match the leader's configured Invert - which is typical when leader and follower are mechanically linked and spin in the same direction.doubleThe frequency at which this control will update. -
Constructor Summary
ConstructorsConstructorDescriptionDifferentialFollower(int LeaderID, MotorAlignmentValue MotorAlignment) Follow the differential motor output of another Talon. -
Method Summary
Modifier and TypeMethodDescriptionclone()Gets information about this control request.getName()Gets the name of this control request.sendRequest(CANBus network, int deviceHash) toString()withLeaderID(int newLeaderID) Modifies this Control Request's LeaderID parameter and returns itself for method-chaining and easier to use request API.withMotorAlignment(MotorAlignmentValue newMotorAlignment) Modifies this Control Request's MotorAlignment parameter and returns itself for method-chaining and easier to use request API.withUpdateFreqHz(double newUpdateFreqHz) Sets the frequency at which this control will update.withUpdateFreqHz(Frequency newUpdateFreqHz) Sets the frequency at which this control will update.
-
Field Details
-
LeaderID
Device ID of the differential leader to follow. -
MotorAlignment
Set to Aligned for motor invert to match the leader's configured Invert - which is typical when leader and follower are mechanically linked and spin in the same direction. Set to Opposed for motor invert to oppose the leader's configured Invert - this is typical where the leader and follower mechanically spin in opposite directions. -
UpdateFreqHz
The frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
-
-
Constructor Details
-
DifferentialFollower
Follow the differential motor output of another Talon.If Talon is in torque control, the differential torque is copied - which will increase the total torque applied. If Talon is in duty cycle output control, the differential duty cycle is matched. If Talon is in voltage output control, the differential motor voltage is matched. Motor direction either matches leader's configured direction or opposes it based on the MotorAlignment.
The leader must enable its DifferentialOutput status signal. The update rate of the status signal determines the update rate of the follower's output and should be no slower than 20 Hz.
- Parameters:
LeaderID- Device ID of the differential leader to follow.MotorAlignment- Set to Aligned for motor invert to match the leader's configured Invert - which is typical when leader and follower are mechanically linked and spin in the same direction. Set to Opposed for motor invert to oppose the leader's configured Invert - this is typical where the leader and follower mechanically spin in opposite directions.
-
-
Method Details
-
getName
Description copied from interface:ControlRequestGets the name of this control request.- Specified by:
getNamein interfaceControlRequest- Returns:
- Name of the control request
-
toString
-
sendRequest
- Specified by:
sendRequestin interfaceControlRequest
-
getControlInfo
Gets information about this control request.- Specified by:
getControlInfoin interfaceControlRequest- Returns:
- Map of control parameter names and corresponding applied values
-
withLeaderID
Modifies this Control Request's LeaderID parameter and returns itself for method-chaining and easier to use request API.Device ID of the differential leader to follow.
- Parameters:
newLeaderID- Parameter to modify- Returns:
- Itself
-
withMotorAlignment
Modifies this Control Request's MotorAlignment parameter and returns itself for method-chaining and easier to use request API.Set to Aligned for motor invert to match the leader's configured Invert - which is typical when leader and follower are mechanically linked and spin in the same direction. Set to Opposed for motor invert to oppose the leader's configured Invert - this is typical where the leader and follower mechanically spin in opposite directions.
- Parameters:
newMotorAlignment- Parameter to modify- Returns:
- Itself
-
withUpdateFreqHz
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
- Specified by:
withUpdateFreqHzin interfaceControlRequest- Parameters:
newUpdateFreqHz- Parameter to modify- Returns:
- Itself
-
withUpdateFreqHz
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
- Specified by:
withUpdateFreqHzin interfaceControlRequest- Parameters:
newUpdateFreqHz- Parameter to modify- Returns:
- Itself
-
clone
-