Class NeutralOut

java.lang.Object
com.ctre.phoenix6.controls.NeutralOut
All Implemented Interfaces:
ControlRequest, Cloneable

public final class NeutralOut extends Object implements ControlRequest, Cloneable
Request neutral output of actuator. The applied brake type is determined by the NeutralMode configuration.
  • Field Details

    • UseTimesync

      public boolean UseTimesync
      Set to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). This eliminates the impact of nondeterministic network delays in exchange for a larger but deterministic control latency.

      This requires setting the ControlTimesyncFreqHz config in MotorOutputConfigs. Additionally, when this is enabled, the UpdateFreqHz of this request should be set to 0 Hz.

    • UpdateFreqHz

      public double UpdateFreqHz
      The frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.

      If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

  • Constructor Details

    • NeutralOut

      public NeutralOut()
      Request neutral output of actuator. The applied brake type is determined by the NeutralMode configuration.
  • Method Details

    • getName

      public String getName()
      Description copied from interface: ControlRequest
      Gets the name of this control request.
      Specified by:
      getName in interface ControlRequest
      Returns:
      Name of the control request
    • toString

      public String toString()
      Overrides:
      toString in class Object
    • sendRequest

      public StatusCode sendRequest(CANBus network, int deviceHash)
      Specified by:
      sendRequest in interface ControlRequest
    • getControlInfo

      Gets information about this control request.
      Specified by:
      getControlInfo in interface ControlRequest
      Returns:
      Map of control parameter names and corresponding applied values
    • withUseTimesync

      public NeutralOut withUseTimesync(boolean newUseTimesync)
      Modifies this Control Request's UseTimesync parameter and returns itself for method-chaining and easier to use request API.

      Set to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). This eliminates the impact of nondeterministic network delays in exchange for a larger but deterministic control latency.

      This requires setting the ControlTimesyncFreqHz config in MotorOutputConfigs. Additionally, when this is enabled, the UpdateFreqHz of this request should be set to 0 Hz.

      Parameters:
      newUseTimesync - Parameter to modify
      Returns:
      Itself
    • withUpdateFreqHz

      public NeutralOut withUpdateFreqHz(double newUpdateFreqHz)
      Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.

      If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

      Specified by:
      withUpdateFreqHz in interface ControlRequest
      Parameters:
      newUpdateFreqHz - Parameter to modify
      Returns:
      Itself
    • withUpdateFreqHz

      public NeutralOut withUpdateFreqHz(Frequency newUpdateFreqHz)
      Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.

      If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

      Specified by:
      withUpdateFreqHz in interface ControlRequest
      Parameters:
      newUpdateFreqHz - Parameter to modify
      Returns:
      Itself
    • clone

      public NeutralOut clone()
      Overrides:
      clone in class Object