Class NeutralOut
- All Implemented Interfaces:
ControlRequest,Cloneable
-
Field Summary
FieldsModifier and TypeFieldDescriptiondoubleThe frequency at which this control will update.booleanSet to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). -
Constructor Summary
Constructors -
Method Summary
Modifier and TypeMethodDescriptionclone()Gets information about this control request.getName()Gets the name of this control request.sendRequest(CANBus network, int deviceHash) toString()withUpdateFreqHz(double newUpdateFreqHz) Sets the frequency at which this control will update.withUpdateFreqHz(Frequency newUpdateFreqHz) Sets the frequency at which this control will update.withUseTimesync(boolean newUseTimesync) Modifies this Control Request's UseTimesync parameter and returns itself for method-chaining and easier to use request API.
-
Field Details
-
UseTimesync
Set to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). This eliminates the impact of nondeterministic network delays in exchange for a larger but deterministic control latency.This requires setting the ControlTimesyncFreqHz config in MotorOutputConfigs. Additionally, when this is enabled, the UpdateFreqHz of this request should be set to 0 Hz.
-
UpdateFreqHz
The frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
-
-
Constructor Details
-
NeutralOut
public NeutralOut()Request neutral output of actuator. The applied brake type is determined by the NeutralMode configuration.
-
-
Method Details
-
getName
Description copied from interface:ControlRequestGets the name of this control request.- Specified by:
getNamein interfaceControlRequest- Returns:
- Name of the control request
-
toString
-
sendRequest
- Specified by:
sendRequestin interfaceControlRequest
-
getControlInfo
Gets information about this control request.- Specified by:
getControlInfoin interfaceControlRequest- Returns:
- Map of control parameter names and corresponding applied values
-
withUseTimesync
Modifies this Control Request's UseTimesync parameter and returns itself for method-chaining and easier to use request API.Set to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). This eliminates the impact of nondeterministic network delays in exchange for a larger but deterministic control latency.
This requires setting the ControlTimesyncFreqHz config in MotorOutputConfigs. Additionally, when this is enabled, the UpdateFreqHz of this request should be set to 0 Hz.
- Parameters:
newUseTimesync- Parameter to modify- Returns:
- Itself
-
withUpdateFreqHz
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
- Specified by:
withUpdateFreqHzin interfaceControlRequest- Parameters:
newUpdateFreqHz- Parameter to modify- Returns:
- Itself
-
withUpdateFreqHz
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.
- Specified by:
withUpdateFreqHzin interfaceControlRequest- Parameters:
newUpdateFreqHz- Parameter to modify- Returns:
- Itself
-
clone
-