001/* 002 * Copyright (C) Cross The Road Electronics. All rights reserved. 003 * License information can be found in CTRE_LICENSE.txt 004 * For support and suggestions contact support@ctr-electronics.com or file 005 * an issue tracker at https://github.com/CrossTheRoadElec/Phoenix-Releases 006 */ 007package com.ctre.phoenix6.hardware.traits; 008 009import com.ctre.phoenix6.StatusCode; 010import com.ctre.phoenix6.controls.*; 011import com.ctre.phoenix6.controls.compound.*; 012 013/** 014 * Contains all control functions available for devices that support Talon 015 * controls. 016 */ 017public interface HasTalonControls extends CommonDevice 018{ 019 020 021 /** 022 * Request a specified motor duty cycle. 023 * <p> 024 * This control mode will output a proportion of the supplied voltage 025 * which is supplied by the user. 026 * <ul> 027 * <li> <b>DutyCycleOut Parameters:</b> 028 * <ul> 029 * <li> <b>Output:</b> Proportion of supply voltage to apply in fractional 030 * units between -1 and +1 031 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 032 * Phoenix Pro), which increases peak power by ~15% 033 * on supported devices (see {@link SupportsFOC}). 034 * Set to false to use trapezoidal commutation. 035 * <p> 036 * FOC improves motor performance by leveraging 037 * torque (current) control. However, this may be 038 * inconvenient for applications that require 039 * specifying duty cycle or voltage. CTR-Electronics 040 * has developed a hybrid method that combines the 041 * performances gains of FOC while still allowing 042 * applications to provide duty cycle or voltage 043 * demand. This not to be confused with simple 044 * sinusoidal control or phase voltage control which 045 * lacks the performance gains. 046 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 047 * rotor when output is zero (or within 048 * deadband). Set to false to use the 049 * NeutralMode configuration setting 050 * (default). This flag exists to 051 * provide the fundamental behavior of 052 * this control when output is zero, 053 * which is to provide 0V to the motor. 054 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 055 * This allows users to use other limit 056 * switch sensors connected to robot 057 * controller. This also allows use of 058 * active sensors that require external 059 * power. 060 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 061 * This allows users to use other limit 062 * switch sensors connected to robot 063 * controller. This also allows use of 064 * active sensors that require external 065 * power. 066 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 067 * switches and the LimitForwardMotion and 068 * LimitReverseMotion parameters, instead 069 * allowing motion. 070 * <p> 071 * This can be useful on mechanisms such 072 * as an intake/feeder, where a limit 073 * switch stops motion while intaking but 074 * should be ignored when feeding to a 075 * shooter. 076 * <p> 077 * The hardware limit faults and 078 * Forward/ReverseLimit signals will still 079 * report the values of the limit switches 080 * regardless of this parameter. 081 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 082 * instead allowing motion. 083 * <p> 084 * This can be useful when calibrating the 085 * zero point of a mechanism such as an 086 * elevator. 087 * <p> 088 * The software limit faults will still 089 * report the values of the software 090 * limits regardless of this parameter. 091 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 092 * request until a timesync boundary (requires 093 * Phoenix Pro and CANivore). This eliminates the 094 * impact of nondeterministic network delays in 095 * exchange for a larger but deterministic control 096 * latency. 097 * <p> 098 * This requires setting the ControlTimesyncFreqHz 099 * config in MotorOutputConfigs. Additionally, when 100 * this is enabled, the UpdateFreqHz of this 101 * request should be set to 0 Hz. 102 * </ul> 103 * </ul> 104 * 105 * @param request Control object to request of the device 106 * @return Status code of the request 107 */ 108 StatusCode setControl(DutyCycleOut request); 109 110 /** 111 * Request a specified voltage. 112 * <p> 113 * This control mode will attempt to apply the specified voltage to 114 * the motor. If the supply voltage is below the requested voltage, 115 * the motor controller will output the supply voltage. 116 * <ul> 117 * <li> <b>VoltageOut Parameters:</b> 118 * <ul> 119 * <li> <b>Output:</b> Voltage to attempt to drive at 120 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 121 * Phoenix Pro), which increases peak power by ~15% 122 * on supported devices (see {@link SupportsFOC}). 123 * Set to false to use trapezoidal commutation. 124 * <p> 125 * FOC improves motor performance by leveraging 126 * torque (current) control. However, this may be 127 * inconvenient for applications that require 128 * specifying duty cycle or voltage. CTR-Electronics 129 * has developed a hybrid method that combines the 130 * performances gains of FOC while still allowing 131 * applications to provide duty cycle or voltage 132 * demand. This not to be confused with simple 133 * sinusoidal control or phase voltage control which 134 * lacks the performance gains. 135 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 136 * rotor when output is zero (or within 137 * deadband). Set to false to use the 138 * NeutralMode configuration setting 139 * (default). This flag exists to 140 * provide the fundamental behavior of 141 * this control when output is zero, 142 * which is to provide 0V to the motor. 143 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 144 * This allows users to use other limit 145 * switch sensors connected to robot 146 * controller. This also allows use of 147 * active sensors that require external 148 * power. 149 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 150 * This allows users to use other limit 151 * switch sensors connected to robot 152 * controller. This also allows use of 153 * active sensors that require external 154 * power. 155 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 156 * switches and the LimitForwardMotion and 157 * LimitReverseMotion parameters, instead 158 * allowing motion. 159 * <p> 160 * This can be useful on mechanisms such 161 * as an intake/feeder, where a limit 162 * switch stops motion while intaking but 163 * should be ignored when feeding to a 164 * shooter. 165 * <p> 166 * The hardware limit faults and 167 * Forward/ReverseLimit signals will still 168 * report the values of the limit switches 169 * regardless of this parameter. 170 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 171 * instead allowing motion. 172 * <p> 173 * This can be useful when calibrating the 174 * zero point of a mechanism such as an 175 * elevator. 176 * <p> 177 * The software limit faults will still 178 * report the values of the software 179 * limits regardless of this parameter. 180 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 181 * request until a timesync boundary (requires 182 * Phoenix Pro and CANivore). This eliminates the 183 * impact of nondeterministic network delays in 184 * exchange for a larger but deterministic control 185 * latency. 186 * <p> 187 * This requires setting the ControlTimesyncFreqHz 188 * config in MotorOutputConfigs. Additionally, when 189 * this is enabled, the UpdateFreqHz of this 190 * request should be set to 0 Hz. 191 * </ul> 192 * </ul> 193 * 194 * @param request Control object to request of the device 195 * @return Status code of the request 196 */ 197 StatusCode setControl(VoltageOut request); 198 199 /** 200 * Request PID to target position with duty cycle feedforward. 201 * <p> 202 * This control mode will set the motor's position setpoint to the 203 * position specified by the user. In addition, it will apply an 204 * additional duty cycle as an arbitrary feedforward value. 205 * <ul> 206 * <li> <b>PositionDutyCycle Parameters:</b> 207 * <ul> 208 * <li> <b>Position:</b> Position to drive toward in rotations. 209 * <li> <b>Velocity:</b> Velocity to drive toward in rotations per second. 210 * This is typically used for motion profiles 211 * generated by the robot program. 212 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 213 * Phoenix Pro), which increases peak power by ~15% 214 * on supported devices (see {@link SupportsFOC}). 215 * Set to false to use trapezoidal commutation. 216 * <p> 217 * FOC improves motor performance by leveraging 218 * torque (current) control. However, this may be 219 * inconvenient for applications that require 220 * specifying duty cycle or voltage. CTR-Electronics 221 * has developed a hybrid method that combines the 222 * performances gains of FOC while still allowing 223 * applications to provide duty cycle or voltage 224 * demand. This not to be confused with simple 225 * sinusoidal control or phase voltage control which 226 * lacks the performance gains. 227 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 228 * -1 and +1. This is added to the output of the 229 * onboard feedforward terms. 230 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 231 * Use the configuration api to set the gain values for 232 * the selected slot before enabling this feature. Slot 233 * must be within [0,2]. 234 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 235 * rotor when output is zero (or within 236 * deadband). Set to false to use the 237 * NeutralMode configuration setting 238 * (default). This flag exists to 239 * provide the fundamental behavior of 240 * this control when output is zero, 241 * which is to provide 0V to the motor. 242 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 243 * This allows users to use other limit 244 * switch sensors connected to robot 245 * controller. This also allows use of 246 * active sensors that require external 247 * power. 248 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 249 * This allows users to use other limit 250 * switch sensors connected to robot 251 * controller. This also allows use of 252 * active sensors that require external 253 * power. 254 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 255 * switches and the LimitForwardMotion and 256 * LimitReverseMotion parameters, instead 257 * allowing motion. 258 * <p> 259 * This can be useful on mechanisms such 260 * as an intake/feeder, where a limit 261 * switch stops motion while intaking but 262 * should be ignored when feeding to a 263 * shooter. 264 * <p> 265 * The hardware limit faults and 266 * Forward/ReverseLimit signals will still 267 * report the values of the limit switches 268 * regardless of this parameter. 269 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 270 * instead allowing motion. 271 * <p> 272 * This can be useful when calibrating the 273 * zero point of a mechanism such as an 274 * elevator. 275 * <p> 276 * The software limit faults will still 277 * report the values of the software 278 * limits regardless of this parameter. 279 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 280 * request until a timesync boundary (requires 281 * Phoenix Pro and CANivore). This eliminates the 282 * impact of nondeterministic network delays in 283 * exchange for a larger but deterministic control 284 * latency. 285 * <p> 286 * This requires setting the ControlTimesyncFreqHz 287 * config in MotorOutputConfigs. Additionally, when 288 * this is enabled, the UpdateFreqHz of this 289 * request should be set to 0 Hz. 290 * </ul> 291 * </ul> 292 * 293 * @param request Control object to request of the device 294 * @return Status code of the request 295 */ 296 StatusCode setControl(PositionDutyCycle request); 297 298 /** 299 * Request PID to target position with voltage feedforward 300 * <p> 301 * This control mode will set the motor's position setpoint to the 302 * position specified by the user. In addition, it will apply an 303 * additional voltage as an arbitrary feedforward value. 304 * <ul> 305 * <li> <b>PositionVoltage Parameters:</b> 306 * <ul> 307 * <li> <b>Position:</b> Position to drive toward in rotations. 308 * <li> <b>Velocity:</b> Velocity to drive toward in rotations per second. 309 * This is typically used for motion profiles 310 * generated by the robot program. 311 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 312 * Phoenix Pro), which increases peak power by ~15% 313 * on supported devices (see {@link SupportsFOC}). 314 * Set to false to use trapezoidal commutation. 315 * <p> 316 * FOC improves motor performance by leveraging 317 * torque (current) control. However, this may be 318 * inconvenient for applications that require 319 * specifying duty cycle or voltage. CTR-Electronics 320 * has developed a hybrid method that combines the 321 * performances gains of FOC while still allowing 322 * applications to provide duty cycle or voltage 323 * demand. This not to be confused with simple 324 * sinusoidal control or phase voltage control which 325 * lacks the performance gains. 326 * <li> <b>FeedForward:</b> Feedforward to apply in volts. This is added to 327 * the output of the onboard feedforward terms. 328 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 329 * Use the configuration api to set the gain values for 330 * the selected slot before enabling this feature. Slot 331 * must be within [0,2]. 332 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 333 * rotor when output is zero (or within 334 * deadband). Set to false to use the 335 * NeutralMode configuration setting 336 * (default). This flag exists to 337 * provide the fundamental behavior of 338 * this control when output is zero, 339 * which is to provide 0V to the motor. 340 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 341 * This allows users to use other limit 342 * switch sensors connected to robot 343 * controller. This also allows use of 344 * active sensors that require external 345 * power. 346 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 347 * This allows users to use other limit 348 * switch sensors connected to robot 349 * controller. This also allows use of 350 * active sensors that require external 351 * power. 352 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 353 * switches and the LimitForwardMotion and 354 * LimitReverseMotion parameters, instead 355 * allowing motion. 356 * <p> 357 * This can be useful on mechanisms such 358 * as an intake/feeder, where a limit 359 * switch stops motion while intaking but 360 * should be ignored when feeding to a 361 * shooter. 362 * <p> 363 * The hardware limit faults and 364 * Forward/ReverseLimit signals will still 365 * report the values of the limit switches 366 * regardless of this parameter. 367 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 368 * instead allowing motion. 369 * <p> 370 * This can be useful when calibrating the 371 * zero point of a mechanism such as an 372 * elevator. 373 * <p> 374 * The software limit faults will still 375 * report the values of the software 376 * limits regardless of this parameter. 377 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 378 * request until a timesync boundary (requires 379 * Phoenix Pro and CANivore). This eliminates the 380 * impact of nondeterministic network delays in 381 * exchange for a larger but deterministic control 382 * latency. 383 * <p> 384 * This requires setting the ControlTimesyncFreqHz 385 * config in MotorOutputConfigs. Additionally, when 386 * this is enabled, the UpdateFreqHz of this 387 * request should be set to 0 Hz. 388 * </ul> 389 * </ul> 390 * 391 * @param request Control object to request of the device 392 * @return Status code of the request 393 */ 394 StatusCode setControl(PositionVoltage request); 395 396 /** 397 * Request PID to target velocity with duty cycle feedforward. 398 * <p> 399 * This control mode will set the motor's velocity setpoint to the 400 * velocity specified by the user. In addition, it will apply an 401 * additional voltage as an arbitrary feedforward value. 402 * <ul> 403 * <li> <b>VelocityDutyCycle Parameters:</b> 404 * <ul> 405 * <li> <b>Velocity:</b> Velocity to drive toward in rotations per second. 406 * <li> <b>Acceleration:</b> Acceleration to drive toward in rotations per 407 * second squared. This is typically used for 408 * motion profiles generated by the robot program. 409 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 410 * Phoenix Pro), which increases peak power by ~15% 411 * on supported devices (see {@link SupportsFOC}). 412 * Set to false to use trapezoidal commutation. 413 * <p> 414 * FOC improves motor performance by leveraging 415 * torque (current) control. However, this may be 416 * inconvenient for applications that require 417 * specifying duty cycle or voltage. CTR-Electronics 418 * has developed a hybrid method that combines the 419 * performances gains of FOC while still allowing 420 * applications to provide duty cycle or voltage 421 * demand. This not to be confused with simple 422 * sinusoidal control or phase voltage control which 423 * lacks the performance gains. 424 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 425 * -1 and +1. This is added to the output of the 426 * onboard feedforward terms. 427 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 428 * Use the configuration api to set the gain values for 429 * the selected slot before enabling this feature. Slot 430 * must be within [0,2]. 431 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 432 * rotor when output is zero (or within 433 * deadband). Set to false to use the 434 * NeutralMode configuration setting 435 * (default). This flag exists to 436 * provide the fundamental behavior of 437 * this control when output is zero, 438 * which is to provide 0V to the motor. 439 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 440 * This allows users to use other limit 441 * switch sensors connected to robot 442 * controller. This also allows use of 443 * active sensors that require external 444 * power. 445 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 446 * This allows users to use other limit 447 * switch sensors connected to robot 448 * controller. This also allows use of 449 * active sensors that require external 450 * power. 451 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 452 * switches and the LimitForwardMotion and 453 * LimitReverseMotion parameters, instead 454 * allowing motion. 455 * <p> 456 * This can be useful on mechanisms such 457 * as an intake/feeder, where a limit 458 * switch stops motion while intaking but 459 * should be ignored when feeding to a 460 * shooter. 461 * <p> 462 * The hardware limit faults and 463 * Forward/ReverseLimit signals will still 464 * report the values of the limit switches 465 * regardless of this parameter. 466 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 467 * instead allowing motion. 468 * <p> 469 * This can be useful when calibrating the 470 * zero point of a mechanism such as an 471 * elevator. 472 * <p> 473 * The software limit faults will still 474 * report the values of the software 475 * limits regardless of this parameter. 476 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 477 * request until a timesync boundary (requires 478 * Phoenix Pro and CANivore). This eliminates the 479 * impact of nondeterministic network delays in 480 * exchange for a larger but deterministic control 481 * latency. 482 * <p> 483 * This requires setting the ControlTimesyncFreqHz 484 * config in MotorOutputConfigs. Additionally, when 485 * this is enabled, the UpdateFreqHz of this 486 * request should be set to 0 Hz. 487 * </ul> 488 * </ul> 489 * 490 * @param request Control object to request of the device 491 * @return Status code of the request 492 */ 493 StatusCode setControl(VelocityDutyCycle request); 494 495 /** 496 * Request PID to target velocity with voltage feedforward. 497 * <p> 498 * This control mode will set the motor's velocity setpoint to the 499 * velocity specified by the user. In addition, it will apply an 500 * additional voltage as an arbitrary feedforward value. 501 * <ul> 502 * <li> <b>VelocityVoltage Parameters:</b> 503 * <ul> 504 * <li> <b>Velocity:</b> Velocity to drive toward in rotations per second. 505 * <li> <b>Acceleration:</b> Acceleration to drive toward in rotations per 506 * second squared. This is typically used for 507 * motion profiles generated by the robot program. 508 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 509 * Phoenix Pro), which increases peak power by ~15% 510 * on supported devices (see {@link SupportsFOC}). 511 * Set to false to use trapezoidal commutation. 512 * <p> 513 * FOC improves motor performance by leveraging 514 * torque (current) control. However, this may be 515 * inconvenient for applications that require 516 * specifying duty cycle or voltage. CTR-Electronics 517 * has developed a hybrid method that combines the 518 * performances gains of FOC while still allowing 519 * applications to provide duty cycle or voltage 520 * demand. This not to be confused with simple 521 * sinusoidal control or phase voltage control which 522 * lacks the performance gains. 523 * <li> <b>FeedForward:</b> Feedforward to apply in volts This is added to 524 * the output of the onboard feedforward terms. 525 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 526 * Use the configuration api to set the gain values for 527 * the selected slot before enabling this feature. Slot 528 * must be within [0,2]. 529 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 530 * rotor when output is zero (or within 531 * deadband). Set to false to use the 532 * NeutralMode configuration setting 533 * (default). This flag exists to 534 * provide the fundamental behavior of 535 * this control when output is zero, 536 * which is to provide 0V to the motor. 537 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 538 * This allows users to use other limit 539 * switch sensors connected to robot 540 * controller. This also allows use of 541 * active sensors that require external 542 * power. 543 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 544 * This allows users to use other limit 545 * switch sensors connected to robot 546 * controller. This also allows use of 547 * active sensors that require external 548 * power. 549 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 550 * switches and the LimitForwardMotion and 551 * LimitReverseMotion parameters, instead 552 * allowing motion. 553 * <p> 554 * This can be useful on mechanisms such 555 * as an intake/feeder, where a limit 556 * switch stops motion while intaking but 557 * should be ignored when feeding to a 558 * shooter. 559 * <p> 560 * The hardware limit faults and 561 * Forward/ReverseLimit signals will still 562 * report the values of the limit switches 563 * regardless of this parameter. 564 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 565 * instead allowing motion. 566 * <p> 567 * This can be useful when calibrating the 568 * zero point of a mechanism such as an 569 * elevator. 570 * <p> 571 * The software limit faults will still 572 * report the values of the software 573 * limits regardless of this parameter. 574 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 575 * request until a timesync boundary (requires 576 * Phoenix Pro and CANivore). This eliminates the 577 * impact of nondeterministic network delays in 578 * exchange for a larger but deterministic control 579 * latency. 580 * <p> 581 * This requires setting the ControlTimesyncFreqHz 582 * config in MotorOutputConfigs. Additionally, when 583 * this is enabled, the UpdateFreqHz of this 584 * request should be set to 0 Hz. 585 * </ul> 586 * </ul> 587 * 588 * @param request Control object to request of the device 589 * @return Status code of the request 590 */ 591 StatusCode setControl(VelocityVoltage request); 592 593 /** 594 * Requests Motion Magic® to target a final position using a motion 595 * profile. Users can optionally provide a duty cycle feedforward. 596 * <p> 597 * Motion Magic® produces a motion profile in real-time while 598 * attempting to honor the Cruise Velocity, Acceleration, and 599 * (optional) Jerk specified via the Motion Magic® configuration 600 * values. This control mode does not use the Expo_kV or Expo_kA 601 * configs. 602 * <p> 603 * Target position can be changed on-the-fly and Motion Magic® will do 604 * its best to adjust the profile. This control mode is duty cycle 605 * based, so relevant closed-loop gains will use fractional duty cycle 606 * for the numerator: +1.0 represents full forward output. 607 * <ul> 608 * <li> <b>MotionMagicDutyCycle Parameters:</b> 609 * <ul> 610 * <li> <b>Position:</b> Position to drive toward in rotations. 611 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 612 * Phoenix Pro), which increases peak power by ~15% 613 * on supported devices (see {@link SupportsFOC}). 614 * Set to false to use trapezoidal commutation. 615 * <p> 616 * FOC improves motor performance by leveraging 617 * torque (current) control. However, this may be 618 * inconvenient for applications that require 619 * specifying duty cycle or voltage. CTR-Electronics 620 * has developed a hybrid method that combines the 621 * performances gains of FOC while still allowing 622 * applications to provide duty cycle or voltage 623 * demand. This not to be confused with simple 624 * sinusoidal control or phase voltage control which 625 * lacks the performance gains. 626 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 627 * -1 and +1. This is added to the output of the 628 * onboard feedforward terms. 629 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 630 * Use the configuration api to set the gain values for 631 * the selected slot before enabling this feature. Slot 632 * must be within [0,2]. 633 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 634 * rotor when output is zero (or within 635 * deadband). Set to false to use the 636 * NeutralMode configuration setting 637 * (default). This flag exists to 638 * provide the fundamental behavior of 639 * this control when output is zero, 640 * which is to provide 0V to the motor. 641 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 642 * This allows users to use other limit 643 * switch sensors connected to robot 644 * controller. This also allows use of 645 * active sensors that require external 646 * power. 647 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 648 * This allows users to use other limit 649 * switch sensors connected to robot 650 * controller. This also allows use of 651 * active sensors that require external 652 * power. 653 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 654 * switches and the LimitForwardMotion and 655 * LimitReverseMotion parameters, instead 656 * allowing motion. 657 * <p> 658 * This can be useful on mechanisms such 659 * as an intake/feeder, where a limit 660 * switch stops motion while intaking but 661 * should be ignored when feeding to a 662 * shooter. 663 * <p> 664 * The hardware limit faults and 665 * Forward/ReverseLimit signals will still 666 * report the values of the limit switches 667 * regardless of this parameter. 668 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 669 * instead allowing motion. 670 * <p> 671 * This can be useful when calibrating the 672 * zero point of a mechanism such as an 673 * elevator. 674 * <p> 675 * The software limit faults will still 676 * report the values of the software 677 * limits regardless of this parameter. 678 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 679 * request until a timesync boundary (requires 680 * Phoenix Pro and CANivore). This eliminates the 681 * impact of nondeterministic network delays in 682 * exchange for a larger but deterministic control 683 * latency. 684 * <p> 685 * This requires setting the ControlTimesyncFreqHz 686 * config in MotorOutputConfigs. Additionally, when 687 * this is enabled, the UpdateFreqHz of this 688 * request should be set to 0 Hz. 689 * </ul> 690 * </ul> 691 * 692 * @param request Control object to request of the device 693 * @return Status code of the request 694 */ 695 StatusCode setControl(MotionMagicDutyCycle request); 696 697 /** 698 * Requests Motion Magic® to target a final position using a motion 699 * profile. Users can optionally provide a voltage feedforward. 700 * <p> 701 * Motion Magic® produces a motion profile in real-time while 702 * attempting to honor the Cruise Velocity, Acceleration, and 703 * (optional) Jerk specified via the Motion Magic® configuration 704 * values. This control mode does not use the Expo_kV or Expo_kA 705 * configs. 706 * <p> 707 * Target position can be changed on-the-fly and Motion Magic® will do 708 * its best to adjust the profile. This control mode is 709 * voltage-based, so relevant closed-loop gains will use Volts for the 710 * numerator. 711 * <ul> 712 * <li> <b>MotionMagicVoltage Parameters:</b> 713 * <ul> 714 * <li> <b>Position:</b> Position to drive toward in rotations. 715 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 716 * Phoenix Pro), which increases peak power by ~15% 717 * on supported devices (see {@link SupportsFOC}). 718 * Set to false to use trapezoidal commutation. 719 * <p> 720 * FOC improves motor performance by leveraging 721 * torque (current) control. However, this may be 722 * inconvenient for applications that require 723 * specifying duty cycle or voltage. CTR-Electronics 724 * has developed a hybrid method that combines the 725 * performances gains of FOC while still allowing 726 * applications to provide duty cycle or voltage 727 * demand. This not to be confused with simple 728 * sinusoidal control or phase voltage control which 729 * lacks the performance gains. 730 * <li> <b>FeedForward:</b> Feedforward to apply in volts. This is added to 731 * the output of the onboard feedforward terms. 732 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 733 * Use the configuration api to set the gain values for 734 * the selected slot before enabling this feature. Slot 735 * must be within [0,2]. 736 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 737 * rotor when output is zero (or within 738 * deadband). Set to false to use the 739 * NeutralMode configuration setting 740 * (default). This flag exists to 741 * provide the fundamental behavior of 742 * this control when output is zero, 743 * which is to provide 0V to the motor. 744 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 745 * This allows users to use other limit 746 * switch sensors connected to robot 747 * controller. This also allows use of 748 * active sensors that require external 749 * power. 750 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 751 * This allows users to use other limit 752 * switch sensors connected to robot 753 * controller. This also allows use of 754 * active sensors that require external 755 * power. 756 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 757 * switches and the LimitForwardMotion and 758 * LimitReverseMotion parameters, instead 759 * allowing motion. 760 * <p> 761 * This can be useful on mechanisms such 762 * as an intake/feeder, where a limit 763 * switch stops motion while intaking but 764 * should be ignored when feeding to a 765 * shooter. 766 * <p> 767 * The hardware limit faults and 768 * Forward/ReverseLimit signals will still 769 * report the values of the limit switches 770 * regardless of this parameter. 771 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 772 * instead allowing motion. 773 * <p> 774 * This can be useful when calibrating the 775 * zero point of a mechanism such as an 776 * elevator. 777 * <p> 778 * The software limit faults will still 779 * report the values of the software 780 * limits regardless of this parameter. 781 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 782 * request until a timesync boundary (requires 783 * Phoenix Pro and CANivore). This eliminates the 784 * impact of nondeterministic network delays in 785 * exchange for a larger but deterministic control 786 * latency. 787 * <p> 788 * This requires setting the ControlTimesyncFreqHz 789 * config in MotorOutputConfigs. Additionally, when 790 * this is enabled, the UpdateFreqHz of this 791 * request should be set to 0 Hz. 792 * </ul> 793 * </ul> 794 * 795 * @param request Control object to request of the device 796 * @return Status code of the request 797 */ 798 StatusCode setControl(MotionMagicVoltage request); 799 800 /** 801 * Requests Motion Magic® to target a final velocity using a motion 802 * profile. This allows smooth transitions between velocity set 803 * points. Users can optionally provide a duty cycle feedforward. 804 * <p> 805 * Motion Magic® Velocity produces a motion profile in real-time while 806 * attempting to honor the specified Acceleration and (optional) Jerk. 807 * This control mode does not use the CruiseVelocity, Expo_kV, or 808 * Expo_kA configs. 809 * <p> 810 * If the specified acceleration is zero, the Acceleration under 811 * Motion Magic® configuration parameter is used instead. This allows 812 * for runtime adjustment of acceleration for advanced users. Jerk is 813 * also specified in the Motion Magic® persistent configuration 814 * values. If Jerk is set to zero, Motion Magic® will produce a 815 * trapezoidal acceleration profile. 816 * <p> 817 * Target velocity can also be changed on-the-fly and Motion Magic® 818 * will do its best to adjust the profile. This control mode is duty 819 * cycle based, so relevant closed-loop gains will use fractional duty 820 * cycle for the numerator: +1.0 represents full forward output. 821 * <ul> 822 * <li> <b>MotionMagicVelocityDutyCycle Parameters:</b> 823 * <ul> 824 * <li> <b>Velocity:</b> Target velocity to drive toward in rotations per 825 * second. This can be changed on-the fly. 826 * <li> <b>Acceleration:</b> This is the absolute Acceleration to use 827 * generating the profile. If this parameter is 828 * zero, the Acceleration persistent configuration 829 * parameter is used instead. Acceleration is in 830 * rotations per second squared. If nonzero, the 831 * signage does not matter as the absolute value 832 * is used. 833 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 834 * Phoenix Pro), which increases peak power by ~15% 835 * on supported devices (see {@link SupportsFOC}). 836 * Set to false to use trapezoidal commutation. 837 * <p> 838 * FOC improves motor performance by leveraging 839 * torque (current) control. However, this may be 840 * inconvenient for applications that require 841 * specifying duty cycle or voltage. CTR-Electronics 842 * has developed a hybrid method that combines the 843 * performances gains of FOC while still allowing 844 * applications to provide duty cycle or voltage 845 * demand. This not to be confused with simple 846 * sinusoidal control or phase voltage control which 847 * lacks the performance gains. 848 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 849 * -1 and +1. This is added to the output of the 850 * onboard feedforward terms. 851 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 852 * Use the configuration api to set the gain values for 853 * the selected slot before enabling this feature. Slot 854 * must be within [0,2]. 855 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 856 * rotor when output is zero (or within 857 * deadband). Set to false to use the 858 * NeutralMode configuration setting 859 * (default). This flag exists to 860 * provide the fundamental behavior of 861 * this control when output is zero, 862 * which is to provide 0V to the motor. 863 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 864 * This allows users to use other limit 865 * switch sensors connected to robot 866 * controller. This also allows use of 867 * active sensors that require external 868 * power. 869 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 870 * This allows users to use other limit 871 * switch sensors connected to robot 872 * controller. This also allows use of 873 * active sensors that require external 874 * power. 875 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 876 * switches and the LimitForwardMotion and 877 * LimitReverseMotion parameters, instead 878 * allowing motion. 879 * <p> 880 * This can be useful on mechanisms such 881 * as an intake/feeder, where a limit 882 * switch stops motion while intaking but 883 * should be ignored when feeding to a 884 * shooter. 885 * <p> 886 * The hardware limit faults and 887 * Forward/ReverseLimit signals will still 888 * report the values of the limit switches 889 * regardless of this parameter. 890 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 891 * instead allowing motion. 892 * <p> 893 * This can be useful when calibrating the 894 * zero point of a mechanism such as an 895 * elevator. 896 * <p> 897 * The software limit faults will still 898 * report the values of the software 899 * limits regardless of this parameter. 900 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 901 * request until a timesync boundary (requires 902 * Phoenix Pro and CANivore). This eliminates the 903 * impact of nondeterministic network delays in 904 * exchange for a larger but deterministic control 905 * latency. 906 * <p> 907 * This requires setting the ControlTimesyncFreqHz 908 * config in MotorOutputConfigs. Additionally, when 909 * this is enabled, the UpdateFreqHz of this 910 * request should be set to 0 Hz. 911 * </ul> 912 * </ul> 913 * 914 * @param request Control object to request of the device 915 * @return Status code of the request 916 */ 917 StatusCode setControl(MotionMagicVelocityDutyCycle request); 918 919 /** 920 * Requests Motion Magic® to target a final velocity using a motion 921 * profile. This allows smooth transitions between velocity set 922 * points. Users can optionally provide a voltage feedforward. 923 * <p> 924 * Motion Magic® Velocity produces a motion profile in real-time while 925 * attempting to honor the specified Acceleration and (optional) Jerk. 926 * This control mode does not use the CruiseVelocity, Expo_kV, or 927 * Expo_kA configs. 928 * <p> 929 * If the specified acceleration is zero, the Acceleration under 930 * Motion Magic® configuration parameter is used instead. This allows 931 * for runtime adjustment of acceleration for advanced users. Jerk is 932 * also specified in the Motion Magic® persistent configuration 933 * values. If Jerk is set to zero, Motion Magic® will produce a 934 * trapezoidal acceleration profile. 935 * <p> 936 * Target velocity can also be changed on-the-fly and Motion Magic® 937 * will do its best to adjust the profile. This control mode is 938 * voltage-based, so relevant closed-loop gains will use Volts for the 939 * numerator. 940 * <ul> 941 * <li> <b>MotionMagicVelocityVoltage Parameters:</b> 942 * <ul> 943 * <li> <b>Velocity:</b> Target velocity to drive toward in rotations per 944 * second. This can be changed on-the fly. 945 * <li> <b>Acceleration:</b> This is the absolute Acceleration to use 946 * generating the profile. If this parameter is 947 * zero, the Acceleration persistent configuration 948 * parameter is used instead. Acceleration is in 949 * rotations per second squared. If nonzero, the 950 * signage does not matter as the absolute value 951 * is used. 952 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 953 * Phoenix Pro), which increases peak power by ~15% 954 * on supported devices (see {@link SupportsFOC}). 955 * Set to false to use trapezoidal commutation. 956 * <p> 957 * FOC improves motor performance by leveraging 958 * torque (current) control. However, this may be 959 * inconvenient for applications that require 960 * specifying duty cycle or voltage. CTR-Electronics 961 * has developed a hybrid method that combines the 962 * performances gains of FOC while still allowing 963 * applications to provide duty cycle or voltage 964 * demand. This not to be confused with simple 965 * sinusoidal control or phase voltage control which 966 * lacks the performance gains. 967 * <li> <b>FeedForward:</b> Feedforward to apply in volts. This is added to 968 * the output of the onboard feedforward terms. 969 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 970 * Use the configuration api to set the gain values for 971 * the selected slot before enabling this feature. Slot 972 * must be within [0,2]. 973 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 974 * rotor when output is zero (or within 975 * deadband). Set to false to use the 976 * NeutralMode configuration setting 977 * (default). This flag exists to 978 * provide the fundamental behavior of 979 * this control when output is zero, 980 * which is to provide 0V to the motor. 981 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 982 * This allows users to use other limit 983 * switch sensors connected to robot 984 * controller. This also allows use of 985 * active sensors that require external 986 * power. 987 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 988 * This allows users to use other limit 989 * switch sensors connected to robot 990 * controller. This also allows use of 991 * active sensors that require external 992 * power. 993 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 994 * switches and the LimitForwardMotion and 995 * LimitReverseMotion parameters, instead 996 * allowing motion. 997 * <p> 998 * This can be useful on mechanisms such 999 * as an intake/feeder, where a limit 1000 * switch stops motion while intaking but 1001 * should be ignored when feeding to a 1002 * shooter. 1003 * <p> 1004 * The hardware limit faults and 1005 * Forward/ReverseLimit signals will still 1006 * report the values of the limit switches 1007 * regardless of this parameter. 1008 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1009 * instead allowing motion. 1010 * <p> 1011 * This can be useful when calibrating the 1012 * zero point of a mechanism such as an 1013 * elevator. 1014 * <p> 1015 * The software limit faults will still 1016 * report the values of the software 1017 * limits regardless of this parameter. 1018 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1019 * request until a timesync boundary (requires 1020 * Phoenix Pro and CANivore). This eliminates the 1021 * impact of nondeterministic network delays in 1022 * exchange for a larger but deterministic control 1023 * latency. 1024 * <p> 1025 * This requires setting the ControlTimesyncFreqHz 1026 * config in MotorOutputConfigs. Additionally, when 1027 * this is enabled, the UpdateFreqHz of this 1028 * request should be set to 0 Hz. 1029 * </ul> 1030 * </ul> 1031 * 1032 * @param request Control object to request of the device 1033 * @return Status code of the request 1034 */ 1035 StatusCode setControl(MotionMagicVelocityVoltage request); 1036 1037 /** 1038 * Requests Motion Magic® to target a final position using an 1039 * exponential motion profile. Users can optionally provide a duty 1040 * cycle feedforward. 1041 * <p> 1042 * Motion Magic® Expo produces a motion profile in real-time while 1043 * attempting to honor the Cruise Velocity (optional) and the 1044 * mechanism kV and kA, specified via the Motion Magic® configuration 1045 * values. Note that unlike the slot gains, the Expo_kV and Expo_kA 1046 * configs are always in output units of Volts. 1047 * <p> 1048 * Setting Cruise Velocity to 0 will allow the profile to run to the 1049 * max possible velocity based on Expo_kV. This control mode does not 1050 * use the Acceleration or Jerk configs. 1051 * <p> 1052 * Target position can be changed on-the-fly and Motion Magic® will do 1053 * its best to adjust the profile. This control mode is duty cycle 1054 * based, so relevant closed-loop gains will use fractional duty cycle 1055 * for the numerator: +1.0 represents full forward output. 1056 * <ul> 1057 * <li> <b>MotionMagicExpoDutyCycle Parameters:</b> 1058 * <ul> 1059 * <li> <b>Position:</b> Position to drive toward in rotations. 1060 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1061 * Phoenix Pro), which increases peak power by ~15% 1062 * on supported devices (see {@link SupportsFOC}). 1063 * Set to false to use trapezoidal commutation. 1064 * <p> 1065 * FOC improves motor performance by leveraging 1066 * torque (current) control. However, this may be 1067 * inconvenient for applications that require 1068 * specifying duty cycle or voltage. CTR-Electronics 1069 * has developed a hybrid method that combines the 1070 * performances gains of FOC while still allowing 1071 * applications to provide duty cycle or voltage 1072 * demand. This not to be confused with simple 1073 * sinusoidal control or phase voltage control which 1074 * lacks the performance gains. 1075 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 1076 * -1 and +1. This is added to the output of the 1077 * onboard feedforward terms. 1078 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 1079 * Use the configuration api to set the gain values for 1080 * the selected slot before enabling this feature. Slot 1081 * must be within [0,2]. 1082 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1083 * rotor when output is zero (or within 1084 * deadband). Set to false to use the 1085 * NeutralMode configuration setting 1086 * (default). This flag exists to 1087 * provide the fundamental behavior of 1088 * this control when output is zero, 1089 * which is to provide 0V to the motor. 1090 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1091 * This allows users to use other limit 1092 * switch sensors connected to robot 1093 * controller. This also allows use of 1094 * active sensors that require external 1095 * power. 1096 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1097 * This allows users to use other limit 1098 * switch sensors connected to robot 1099 * controller. This also allows use of 1100 * active sensors that require external 1101 * power. 1102 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1103 * switches and the LimitForwardMotion and 1104 * LimitReverseMotion parameters, instead 1105 * allowing motion. 1106 * <p> 1107 * This can be useful on mechanisms such 1108 * as an intake/feeder, where a limit 1109 * switch stops motion while intaking but 1110 * should be ignored when feeding to a 1111 * shooter. 1112 * <p> 1113 * The hardware limit faults and 1114 * Forward/ReverseLimit signals will still 1115 * report the values of the limit switches 1116 * regardless of this parameter. 1117 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1118 * instead allowing motion. 1119 * <p> 1120 * This can be useful when calibrating the 1121 * zero point of a mechanism such as an 1122 * elevator. 1123 * <p> 1124 * The software limit faults will still 1125 * report the values of the software 1126 * limits regardless of this parameter. 1127 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1128 * request until a timesync boundary (requires 1129 * Phoenix Pro and CANivore). This eliminates the 1130 * impact of nondeterministic network delays in 1131 * exchange for a larger but deterministic control 1132 * latency. 1133 * <p> 1134 * This requires setting the ControlTimesyncFreqHz 1135 * config in MotorOutputConfigs. Additionally, when 1136 * this is enabled, the UpdateFreqHz of this 1137 * request should be set to 0 Hz. 1138 * </ul> 1139 * </ul> 1140 * 1141 * @param request Control object to request of the device 1142 * @return Status code of the request 1143 */ 1144 StatusCode setControl(MotionMagicExpoDutyCycle request); 1145 1146 /** 1147 * Requests Motion Magic® to target a final position using an 1148 * exponential motion profile. Users can optionally provide a voltage 1149 * feedforward. 1150 * <p> 1151 * Motion Magic® Expo produces a motion profile in real-time while 1152 * attempting to honor the Cruise Velocity (optional) and the 1153 * mechanism kV and kA, specified via the Motion Magic® configuration 1154 * values. Note that unlike the slot gains, the Expo_kV and Expo_kA 1155 * configs are always in output units of Volts. 1156 * <p> 1157 * Setting Cruise Velocity to 0 will allow the profile to run to the 1158 * max possible velocity based on Expo_kV. This control mode does not 1159 * use the Acceleration or Jerk configs. 1160 * <p> 1161 * Target position can be changed on-the-fly and Motion Magic® will do 1162 * its best to adjust the profile. This control mode is 1163 * voltage-based, so relevant closed-loop gains will use Volts for the 1164 * numerator. 1165 * <ul> 1166 * <li> <b>MotionMagicExpoVoltage Parameters:</b> 1167 * <ul> 1168 * <li> <b>Position:</b> Position to drive toward in rotations. 1169 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1170 * Phoenix Pro), which increases peak power by ~15% 1171 * on supported devices (see {@link SupportsFOC}). 1172 * Set to false to use trapezoidal commutation. 1173 * <p> 1174 * FOC improves motor performance by leveraging 1175 * torque (current) control. However, this may be 1176 * inconvenient for applications that require 1177 * specifying duty cycle or voltage. CTR-Electronics 1178 * has developed a hybrid method that combines the 1179 * performances gains of FOC while still allowing 1180 * applications to provide duty cycle or voltage 1181 * demand. This not to be confused with simple 1182 * sinusoidal control or phase voltage control which 1183 * lacks the performance gains. 1184 * <li> <b>FeedForward:</b> Feedforward to apply in volts. This is added to 1185 * the output of the onboard feedforward terms. 1186 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 1187 * Use the configuration api to set the gain values for 1188 * the selected slot before enabling this feature. Slot 1189 * must be within [0,2]. 1190 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1191 * rotor when output is zero (or within 1192 * deadband). Set to false to use the 1193 * NeutralMode configuration setting 1194 * (default). This flag exists to 1195 * provide the fundamental behavior of 1196 * this control when output is zero, 1197 * which is to provide 0V to the motor. 1198 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1199 * This allows users to use other limit 1200 * switch sensors connected to robot 1201 * controller. This also allows use of 1202 * active sensors that require external 1203 * power. 1204 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1205 * This allows users to use other limit 1206 * switch sensors connected to robot 1207 * controller. This also allows use of 1208 * active sensors that require external 1209 * power. 1210 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1211 * switches and the LimitForwardMotion and 1212 * LimitReverseMotion parameters, instead 1213 * allowing motion. 1214 * <p> 1215 * This can be useful on mechanisms such 1216 * as an intake/feeder, where a limit 1217 * switch stops motion while intaking but 1218 * should be ignored when feeding to a 1219 * shooter. 1220 * <p> 1221 * The hardware limit faults and 1222 * Forward/ReverseLimit signals will still 1223 * report the values of the limit switches 1224 * regardless of this parameter. 1225 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1226 * instead allowing motion. 1227 * <p> 1228 * This can be useful when calibrating the 1229 * zero point of a mechanism such as an 1230 * elevator. 1231 * <p> 1232 * The software limit faults will still 1233 * report the values of the software 1234 * limits regardless of this parameter. 1235 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1236 * request until a timesync boundary (requires 1237 * Phoenix Pro and CANivore). This eliminates the 1238 * impact of nondeterministic network delays in 1239 * exchange for a larger but deterministic control 1240 * latency. 1241 * <p> 1242 * This requires setting the ControlTimesyncFreqHz 1243 * config in MotorOutputConfigs. Additionally, when 1244 * this is enabled, the UpdateFreqHz of this 1245 * request should be set to 0 Hz. 1246 * </ul> 1247 * </ul> 1248 * 1249 * @param request Control object to request of the device 1250 * @return Status code of the request 1251 */ 1252 StatusCode setControl(MotionMagicExpoVoltage request); 1253 1254 /** 1255 * Requests Motion Magic® to target a final position using a motion 1256 * profile. This dynamic request allows runtime changes to Cruise 1257 * Velocity, Acceleration, and (optional) Jerk. Users can optionally 1258 * provide a duty cycle feedforward. 1259 * <p> 1260 * Motion Magic® produces a motion profile in real-time while 1261 * attempting to honor the specified Cruise Velocity, Acceleration, 1262 * and (optional) Jerk. This control mode does not use the Expo_kV or 1263 * Expo_kA configs. 1264 * <p> 1265 * Target position can be changed on-the-fly and Motion Magic® will do 1266 * its best to adjust the profile. This control mode is duty cycle 1267 * based, so relevant closed-loop gains will use fractional duty cycle 1268 * for the numerator: +1.0 represents full forward output. 1269 * <ul> 1270 * <li> <b>DynamicMotionMagicDutyCycle Parameters:</b> 1271 * <ul> 1272 * <li> <b>Position:</b> Position to drive toward in rotations. 1273 * <li> <b>Velocity:</b> Cruise velocity for profiling. The signage does 1274 * not matter as the device will use the absolute 1275 * value for profile generation. 1276 * <li> <b>Acceleration:</b> Acceleration for profiling. The signage does 1277 * not matter as the device will use the absolute 1278 * value for profile generation 1279 * <li> <b>Jerk:</b> Jerk for profiling. The signage does not matter as the 1280 * device will use the absolute value for profile 1281 * generation. 1282 * <p> 1283 * Jerk is optional; if this is set to zero, then Motion 1284 * Magic® will not apply a Jerk limit. 1285 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1286 * Phoenix Pro), which increases peak power by ~15% 1287 * on supported devices (see {@link SupportsFOC}). 1288 * Set to false to use trapezoidal commutation. 1289 * <p> 1290 * FOC improves motor performance by leveraging 1291 * torque (current) control. However, this may be 1292 * inconvenient for applications that require 1293 * specifying duty cycle or voltage. CTR-Electronics 1294 * has developed a hybrid method that combines the 1295 * performances gains of FOC while still allowing 1296 * applications to provide duty cycle or voltage 1297 * demand. This not to be confused with simple 1298 * sinusoidal control or phase voltage control which 1299 * lacks the performance gains. 1300 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 1301 * -1 and +1. This is added to the output of the 1302 * onboard feedforward terms. 1303 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 1304 * Use the configuration api to set the gain values for 1305 * the selected slot before enabling this feature. Slot 1306 * must be within [0,2]. 1307 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1308 * rotor when output is zero (or within 1309 * deadband). Set to false to use the 1310 * NeutralMode configuration setting 1311 * (default). This flag exists to 1312 * provide the fundamental behavior of 1313 * this control when output is zero, 1314 * which is to provide 0V to the motor. 1315 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1316 * This allows users to use other limit 1317 * switch sensors connected to robot 1318 * controller. This also allows use of 1319 * active sensors that require external 1320 * power. 1321 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1322 * This allows users to use other limit 1323 * switch sensors connected to robot 1324 * controller. This also allows use of 1325 * active sensors that require external 1326 * power. 1327 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1328 * switches and the LimitForwardMotion and 1329 * LimitReverseMotion parameters, instead 1330 * allowing motion. 1331 * <p> 1332 * This can be useful on mechanisms such 1333 * as an intake/feeder, where a limit 1334 * switch stops motion while intaking but 1335 * should be ignored when feeding to a 1336 * shooter. 1337 * <p> 1338 * The hardware limit faults and 1339 * Forward/ReverseLimit signals will still 1340 * report the values of the limit switches 1341 * regardless of this parameter. 1342 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1343 * instead allowing motion. 1344 * <p> 1345 * This can be useful when calibrating the 1346 * zero point of a mechanism such as an 1347 * elevator. 1348 * <p> 1349 * The software limit faults will still 1350 * report the values of the software 1351 * limits regardless of this parameter. 1352 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1353 * request until a timesync boundary (requires 1354 * Phoenix Pro and CANivore). This eliminates the 1355 * impact of nondeterministic network delays in 1356 * exchange for a larger but deterministic control 1357 * latency. 1358 * <p> 1359 * This requires setting the ControlTimesyncFreqHz 1360 * config in MotorOutputConfigs. Additionally, when 1361 * this is enabled, the UpdateFreqHz of this 1362 * request should be set to 0 Hz. 1363 * </ul> 1364 * </ul> 1365 * 1366 * @param request Control object to request of the device 1367 * @return Status code of the request 1368 */ 1369 StatusCode setControl(DynamicMotionMagicDutyCycle request); 1370 1371 /** 1372 * Requests Motion Magic® to target a final position using a motion 1373 * profile. This dynamic request allows runtime changes to Cruise 1374 * Velocity, Acceleration, and (optional) Jerk. Users can optionally 1375 * provide a voltage feedforward. 1376 * <p> 1377 * Motion Magic® produces a motion profile in real-time while 1378 * attempting to honor the specified Cruise Velocity, Acceleration, 1379 * and (optional) Jerk. This control mode does not use the Expo_kV or 1380 * Expo_kA configs. 1381 * <p> 1382 * Target position can be changed on-the-fly and Motion Magic® will do 1383 * its best to adjust the profile. This control mode is 1384 * voltage-based, so relevant closed-loop gains will use Volts for the 1385 * numerator. 1386 * <ul> 1387 * <li> <b>DynamicMotionMagicVoltage Parameters:</b> 1388 * <ul> 1389 * <li> <b>Position:</b> Position to drive toward in rotations. 1390 * <li> <b>Velocity:</b> Cruise velocity for profiling. The signage does 1391 * not matter as the device will use the absolute 1392 * value for profile generation. 1393 * <li> <b>Acceleration:</b> Acceleration for profiling. The signage does 1394 * not matter as the device will use the absolute 1395 * value for profile generation. 1396 * <li> <b>Jerk:</b> Jerk for profiling. The signage does not matter as the 1397 * device will use the absolute value for profile 1398 * generation. 1399 * <p> 1400 * Jerk is optional; if this is set to zero, then Motion 1401 * Magic® will not apply a Jerk limit. 1402 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1403 * Phoenix Pro), which increases peak power by ~15% 1404 * on supported devices (see {@link SupportsFOC}). 1405 * Set to false to use trapezoidal commutation. 1406 * <p> 1407 * FOC improves motor performance by leveraging 1408 * torque (current) control. However, this may be 1409 * inconvenient for applications that require 1410 * specifying duty cycle or voltage. CTR-Electronics 1411 * has developed a hybrid method that combines the 1412 * performances gains of FOC while still allowing 1413 * applications to provide duty cycle or voltage 1414 * demand. This not to be confused with simple 1415 * sinusoidal control or phase voltage control which 1416 * lacks the performance gains. 1417 * <li> <b>FeedForward:</b> Feedforward to apply in volts. This is added to 1418 * the output of the onboard feedforward terms. 1419 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 1420 * Use the configuration api to set the gain values for 1421 * the selected slot before enabling this feature. Slot 1422 * must be within [0,2]. 1423 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1424 * rotor when output is zero (or within 1425 * deadband). Set to false to use the 1426 * NeutralMode configuration setting 1427 * (default). This flag exists to 1428 * provide the fundamental behavior of 1429 * this control when output is zero, 1430 * which is to provide 0V to the motor. 1431 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1432 * This allows users to use other limit 1433 * switch sensors connected to robot 1434 * controller. This also allows use of 1435 * active sensors that require external 1436 * power. 1437 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1438 * This allows users to use other limit 1439 * switch sensors connected to robot 1440 * controller. This also allows use of 1441 * active sensors that require external 1442 * power. 1443 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1444 * switches and the LimitForwardMotion and 1445 * LimitReverseMotion parameters, instead 1446 * allowing motion. 1447 * <p> 1448 * This can be useful on mechanisms such 1449 * as an intake/feeder, where a limit 1450 * switch stops motion while intaking but 1451 * should be ignored when feeding to a 1452 * shooter. 1453 * <p> 1454 * The hardware limit faults and 1455 * Forward/ReverseLimit signals will still 1456 * report the values of the limit switches 1457 * regardless of this parameter. 1458 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1459 * instead allowing motion. 1460 * <p> 1461 * This can be useful when calibrating the 1462 * zero point of a mechanism such as an 1463 * elevator. 1464 * <p> 1465 * The software limit faults will still 1466 * report the values of the software 1467 * limits regardless of this parameter. 1468 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1469 * request until a timesync boundary (requires 1470 * Phoenix Pro and CANivore). This eliminates the 1471 * impact of nondeterministic network delays in 1472 * exchange for a larger but deterministic control 1473 * latency. 1474 * <p> 1475 * This requires setting the ControlTimesyncFreqHz 1476 * config in MotorOutputConfigs. Additionally, when 1477 * this is enabled, the UpdateFreqHz of this 1478 * request should be set to 0 Hz. 1479 * </ul> 1480 * </ul> 1481 * 1482 * @param request Control object to request of the device 1483 * @return Status code of the request 1484 */ 1485 StatusCode setControl(DynamicMotionMagicVoltage request); 1486 1487 /** 1488 * Requests Motion Magic® Expo to target a final position using an 1489 * exponential motion profile. This dynamic request allows runtime 1490 * changes to the profile kV, kA, and (optional) Cruise Velocity. 1491 * Users can optionally provide a duty cycle feedforward. 1492 * <p> 1493 * Motion Magic® Expo produces a motion profile in real-time while 1494 * attempting to honor the specified Cruise Velocity (optional) and 1495 * the mechanism kV and kA. Note that unlike the slot gains, the 1496 * Expo_kV and Expo_kA parameters are always in output units of Volts. 1497 * <p> 1498 * Setting the Cruise Velocity to 0 will allow the profile to run to 1499 * the max possible velocity based on Expo_kV. This control mode does 1500 * not use the Acceleration or Jerk configs. 1501 * <p> 1502 * Target position can be changed on-the-fly and Motion Magic® will do 1503 * its best to adjust the profile. This control mode is duty cycle 1504 * based, so relevant closed-loop gains will use fractional duty cycle 1505 * for the numerator: +1.0 represents full forward output. 1506 * <ul> 1507 * <li> <b>DynamicMotionMagicExpoDutyCycle Parameters:</b> 1508 * <ul> 1509 * <li> <b>Position:</b> Position to drive toward in rotations. 1510 * <li> <b>kV:</b> Mechanism kV for profiling. Unlike the kV slot gain, 1511 * this is always in units of V/rps. 1512 * <p> 1513 * This represents the amount of voltage necessary to hold a 1514 * velocity. In terms of the Motion Magic® Expo profile, a 1515 * higher kV results in a slower maximum velocity. 1516 * <li> <b>kA:</b> Mechanism kA for profiling. Unlike the kA slot gain, 1517 * this is always in units of V/rps². 1518 * <p> 1519 * This represents the amount of voltage necessary to 1520 * achieve an acceleration. In terms of the Motion Magic® 1521 * Expo profile, a higher kA results in a slower 1522 * acceleration. 1523 * <li> <b>Velocity:</b> Cruise velocity for profiling. The signage does 1524 * not matter as the device will use the absolute 1525 * value for profile generation. Setting this to 0 1526 * will allow the profile to run to the max possible 1527 * velocity based on Expo_kV. 1528 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1529 * Phoenix Pro), which increases peak power by ~15% 1530 * on supported devices (see {@link SupportsFOC}). 1531 * Set to false to use trapezoidal commutation. 1532 * <p> 1533 * FOC improves motor performance by leveraging 1534 * torque (current) control. However, this may be 1535 * inconvenient for applications that require 1536 * specifying duty cycle or voltage. CTR-Electronics 1537 * has developed a hybrid method that combines the 1538 * performances gains of FOC while still allowing 1539 * applications to provide duty cycle or voltage 1540 * demand. This not to be confused with simple 1541 * sinusoidal control or phase voltage control which 1542 * lacks the performance gains. 1543 * <li> <b>FeedForward:</b> Feedforward to apply in fractional units between 1544 * -1 and +1. This is added to the output of the 1545 * onboard feedforward terms. 1546 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 1547 * Use the configuration api to set the gain values for 1548 * the selected slot before enabling this feature. Slot 1549 * must be within [0,2]. 1550 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1551 * rotor when output is zero (or within 1552 * deadband). Set to false to use the 1553 * NeutralMode configuration setting 1554 * (default). This flag exists to 1555 * provide the fundamental behavior of 1556 * this control when output is zero, 1557 * which is to provide 0V to the motor. 1558 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1559 * This allows users to use other limit 1560 * switch sensors connected to robot 1561 * controller. This also allows use of 1562 * active sensors that require external 1563 * power. 1564 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1565 * This allows users to use other limit 1566 * switch sensors connected to robot 1567 * controller. This also allows use of 1568 * active sensors that require external 1569 * power. 1570 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1571 * switches and the LimitForwardMotion and 1572 * LimitReverseMotion parameters, instead 1573 * allowing motion. 1574 * <p> 1575 * This can be useful on mechanisms such 1576 * as an intake/feeder, where a limit 1577 * switch stops motion while intaking but 1578 * should be ignored when feeding to a 1579 * shooter. 1580 * <p> 1581 * The hardware limit faults and 1582 * Forward/ReverseLimit signals will still 1583 * report the values of the limit switches 1584 * regardless of this parameter. 1585 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1586 * instead allowing motion. 1587 * <p> 1588 * This can be useful when calibrating the 1589 * zero point of a mechanism such as an 1590 * elevator. 1591 * <p> 1592 * The software limit faults will still 1593 * report the values of the software 1594 * limits regardless of this parameter. 1595 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1596 * request until a timesync boundary (requires 1597 * Phoenix Pro and CANivore). This eliminates the 1598 * impact of nondeterministic network delays in 1599 * exchange for a larger but deterministic control 1600 * latency. 1601 * <p> 1602 * This requires setting the ControlTimesyncFreqHz 1603 * config in MotorOutputConfigs. Additionally, when 1604 * this is enabled, the UpdateFreqHz of this 1605 * request should be set to 0 Hz. 1606 * </ul> 1607 * </ul> 1608 * 1609 * @param request Control object to request of the device 1610 * @return Status code of the request 1611 */ 1612 StatusCode setControl(DynamicMotionMagicExpoDutyCycle request); 1613 1614 /** 1615 * Requests Motion Magic® Expo to target a final position using an 1616 * exponential motion profile. This dynamic request allows runtime 1617 * changes to the profile kV, kA, and (optional) Cruise Velocity. 1618 * Users can optionally provide a voltage feedforward. 1619 * <p> 1620 * Motion Magic® Expo produces a motion profile in real-time while 1621 * attempting to honor the specified Cruise Velocity (optional) and 1622 * the mechanism kV and kA. Note that unlike the slot gains, the 1623 * Expo_kV and Expo_kA parameters are always in output units of Volts. 1624 * <p> 1625 * Setting the Cruise Velocity to 0 will allow the profile to run to 1626 * the max possible velocity based on Expo_kV. This control mode does 1627 * not use the Acceleration or Jerk configs. 1628 * <p> 1629 * Target position can be changed on-the-fly and Motion Magic® will do 1630 * its best to adjust the profile. This control mode is 1631 * voltage-based, so relevant closed-loop gains will use Volts for the 1632 * numerator. 1633 * <ul> 1634 * <li> <b>DynamicMotionMagicExpoVoltage Parameters:</b> 1635 * <ul> 1636 * <li> <b>Position:</b> Position to drive toward in rotations. 1637 * <li> <b>kV:</b> Mechanism kV for profiling. Unlike the kV slot gain, 1638 * this is always in units of V/rps. 1639 * <p> 1640 * This represents the amount of voltage necessary to hold a 1641 * velocity. In terms of the Motion Magic® Expo profile, a 1642 * higher kV results in a slower maximum velocity. 1643 * <li> <b>kA:</b> Mechanism kA for profiling. Unlike the kA slot gain, 1644 * this is always in units of V/rps². 1645 * <p> 1646 * This represents the amount of voltage necessary to 1647 * achieve an acceleration. In terms of the Motion Magic® 1648 * Expo profile, a higher kA results in a slower 1649 * acceleration. 1650 * <li> <b>Velocity:</b> Cruise velocity for profiling. The signage does 1651 * not matter as the device will use the absolute 1652 * value for profile generation. Setting this to 0 1653 * will allow the profile to run to the max possible 1654 * velocity based on Expo_kV. 1655 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1656 * Phoenix Pro), which increases peak power by ~15% 1657 * on supported devices (see {@link SupportsFOC}). 1658 * Set to false to use trapezoidal commutation. 1659 * <p> 1660 * FOC improves motor performance by leveraging 1661 * torque (current) control. However, this may be 1662 * inconvenient for applications that require 1663 * specifying duty cycle or voltage. CTR-Electronics 1664 * has developed a hybrid method that combines the 1665 * performances gains of FOC while still allowing 1666 * applications to provide duty cycle or voltage 1667 * demand. This not to be confused with simple 1668 * sinusoidal control or phase voltage control which 1669 * lacks the performance gains. 1670 * <li> <b>FeedForward:</b> Feedforward to apply in volts. This is added to 1671 * the output of the onboard feedforward terms. 1672 * <li> <b>Slot:</b> Select which gains are applied by selecting the slot. 1673 * Use the configuration api to set the gain values for 1674 * the selected slot before enabling this feature. Slot 1675 * must be within [0,2]. 1676 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1677 * rotor when output is zero (or within 1678 * deadband). Set to false to use the 1679 * NeutralMode configuration setting 1680 * (default). This flag exists to 1681 * provide the fundamental behavior of 1682 * this control when output is zero, 1683 * which is to provide 0V to the motor. 1684 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1685 * This allows users to use other limit 1686 * switch sensors connected to robot 1687 * controller. This also allows use of 1688 * active sensors that require external 1689 * power. 1690 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1691 * This allows users to use other limit 1692 * switch sensors connected to robot 1693 * controller. This also allows use of 1694 * active sensors that require external 1695 * power. 1696 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1697 * switches and the LimitForwardMotion and 1698 * LimitReverseMotion parameters, instead 1699 * allowing motion. 1700 * <p> 1701 * This can be useful on mechanisms such 1702 * as an intake/feeder, where a limit 1703 * switch stops motion while intaking but 1704 * should be ignored when feeding to a 1705 * shooter. 1706 * <p> 1707 * The hardware limit faults and 1708 * Forward/ReverseLimit signals will still 1709 * report the values of the limit switches 1710 * regardless of this parameter. 1711 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1712 * instead allowing motion. 1713 * <p> 1714 * This can be useful when calibrating the 1715 * zero point of a mechanism such as an 1716 * elevator. 1717 * <p> 1718 * The software limit faults will still 1719 * report the values of the software 1720 * limits regardless of this parameter. 1721 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1722 * request until a timesync boundary (requires 1723 * Phoenix Pro and CANivore). This eliminates the 1724 * impact of nondeterministic network delays in 1725 * exchange for a larger but deterministic control 1726 * latency. 1727 * <p> 1728 * This requires setting the ControlTimesyncFreqHz 1729 * config in MotorOutputConfigs. Additionally, when 1730 * this is enabled, the UpdateFreqHz of this 1731 * request should be set to 0 Hz. 1732 * </ul> 1733 * </ul> 1734 * 1735 * @param request Control object to request of the device 1736 * @return Status code of the request 1737 */ 1738 StatusCode setControl(DynamicMotionMagicExpoVoltage request); 1739 1740 /** 1741 * Request a specified motor duty cycle with a differential position 1742 * closed-loop. 1743 * <p> 1744 * This control mode will output a proportion of the supplied voltage 1745 * which is supplied by the user. It will also set the motor's 1746 * differential position setpoint to the specified position. 1747 * <ul> 1748 * <li> <b>DifferentialDutyCycle Parameters:</b> 1749 * <ul> 1750 * <li> <b>AverageOutput:</b> Proportion of supply voltage to apply on the 1751 * Average axis in fractional units between -1 1752 * and +1. 1753 * <li> <b>DifferentialPosition:</b> Differential position to drive towards 1754 * in rotations. 1755 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1756 * Phoenix Pro), which increases peak power by ~15% 1757 * on supported devices (see {@link SupportsFOC}). 1758 * Set to false to use trapezoidal commutation. 1759 * <p> 1760 * FOC improves motor performance by leveraging 1761 * torque (current) control. However, this may be 1762 * inconvenient for applications that require 1763 * specifying duty cycle or voltage. CTR-Electronics 1764 * has developed a hybrid method that combines the 1765 * performances gains of FOC while still allowing 1766 * applications to provide duty cycle or voltage 1767 * demand. This not to be confused with simple 1768 * sinusoidal control or phase voltage control which 1769 * lacks the performance gains. 1770 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 1771 * differential controller by selecting the 1772 * slot. Use the configuration api to set the 1773 * gain values for the selected slot before 1774 * enabling this feature. Slot must be within 1775 * [0,2]. 1776 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1777 * rotor when output is zero (or within 1778 * deadband). Set to false to use the 1779 * NeutralMode configuration setting 1780 * (default). This flag exists to 1781 * provide the fundamental behavior of 1782 * this control when output is zero, 1783 * which is to provide 0V to the motor. 1784 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1785 * This allows users to use other limit 1786 * switch sensors connected to robot 1787 * controller. This also allows use of 1788 * active sensors that require external 1789 * power. 1790 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1791 * This allows users to use other limit 1792 * switch sensors connected to robot 1793 * controller. This also allows use of 1794 * active sensors that require external 1795 * power. 1796 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1797 * switches and the LimitForwardMotion and 1798 * LimitReverseMotion parameters, instead 1799 * allowing motion. 1800 * <p> 1801 * This can be useful on mechanisms such 1802 * as an intake/feeder, where a limit 1803 * switch stops motion while intaking but 1804 * should be ignored when feeding to a 1805 * shooter. 1806 * <p> 1807 * The hardware limit faults and 1808 * Forward/ReverseLimit signals will still 1809 * report the values of the limit switches 1810 * regardless of this parameter. 1811 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1812 * instead allowing motion. 1813 * <p> 1814 * This can be useful when calibrating the 1815 * zero point of a mechanism such as an 1816 * elevator. 1817 * <p> 1818 * The software limit faults will still 1819 * report the values of the software 1820 * limits regardless of this parameter. 1821 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1822 * request until a timesync boundary (requires 1823 * Phoenix Pro and CANivore). This eliminates the 1824 * impact of nondeterministic network delays in 1825 * exchange for a larger but deterministic control 1826 * latency. 1827 * <p> 1828 * This requires setting the ControlTimesyncFreqHz 1829 * config in MotorOutputConfigs. Additionally, when 1830 * this is enabled, the UpdateFreqHz of this 1831 * request should be set to 0 Hz. 1832 * </ul> 1833 * </ul> 1834 * 1835 * @param request Control object to request of the device 1836 * @return Status code of the request 1837 */ 1838 StatusCode setControl(DifferentialDutyCycle request); 1839 1840 /** 1841 * Request a specified voltage with a differential position 1842 * closed-loop. 1843 * <p> 1844 * This control mode will attempt to apply the specified voltage to 1845 * the motor. If the supply voltage is below the requested voltage, 1846 * the motor controller will output the supply voltage. It will also 1847 * set the motor's differential position setpoint to the specified 1848 * position. 1849 * <ul> 1850 * <li> <b>DifferentialVoltage Parameters:</b> 1851 * <ul> 1852 * <li> <b>AverageOutput:</b> Voltage to attempt to drive at on the Average 1853 * axis. 1854 * <li> <b>DifferentialPosition:</b> Differential position to drive towards 1855 * in rotations. 1856 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1857 * Phoenix Pro), which increases peak power by ~15% 1858 * on supported devices (see {@link SupportsFOC}). 1859 * Set to false to use trapezoidal commutation. 1860 * <p> 1861 * FOC improves motor performance by leveraging 1862 * torque (current) control. However, this may be 1863 * inconvenient for applications that require 1864 * specifying duty cycle or voltage. CTR-Electronics 1865 * has developed a hybrid method that combines the 1866 * performances gains of FOC while still allowing 1867 * applications to provide duty cycle or voltage 1868 * demand. This not to be confused with simple 1869 * sinusoidal control or phase voltage control which 1870 * lacks the performance gains. 1871 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 1872 * differential controller by selecting the 1873 * slot. Use the configuration api to set the 1874 * gain values for the selected slot before 1875 * enabling this feature. Slot must be within 1876 * [0,2]. 1877 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1878 * rotor when output is zero (or within 1879 * deadband). Set to false to use the 1880 * NeutralMode configuration setting 1881 * (default). This flag exists to 1882 * provide the fundamental behavior of 1883 * this control when output is zero, 1884 * which is to provide 0V to the motor. 1885 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1886 * This allows users to use other limit 1887 * switch sensors connected to robot 1888 * controller. This also allows use of 1889 * active sensors that require external 1890 * power. 1891 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1892 * This allows users to use other limit 1893 * switch sensors connected to robot 1894 * controller. This also allows use of 1895 * active sensors that require external 1896 * power. 1897 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 1898 * switches and the LimitForwardMotion and 1899 * LimitReverseMotion parameters, instead 1900 * allowing motion. 1901 * <p> 1902 * This can be useful on mechanisms such 1903 * as an intake/feeder, where a limit 1904 * switch stops motion while intaking but 1905 * should be ignored when feeding to a 1906 * shooter. 1907 * <p> 1908 * The hardware limit faults and 1909 * Forward/ReverseLimit signals will still 1910 * report the values of the limit switches 1911 * regardless of this parameter. 1912 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 1913 * instead allowing motion. 1914 * <p> 1915 * This can be useful when calibrating the 1916 * zero point of a mechanism such as an 1917 * elevator. 1918 * <p> 1919 * The software limit faults will still 1920 * report the values of the software 1921 * limits regardless of this parameter. 1922 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 1923 * request until a timesync boundary (requires 1924 * Phoenix Pro and CANivore). This eliminates the 1925 * impact of nondeterministic network delays in 1926 * exchange for a larger but deterministic control 1927 * latency. 1928 * <p> 1929 * This requires setting the ControlTimesyncFreqHz 1930 * config in MotorOutputConfigs. Additionally, when 1931 * this is enabled, the UpdateFreqHz of this 1932 * request should be set to 0 Hz. 1933 * </ul> 1934 * </ul> 1935 * 1936 * @param request Control object to request of the device 1937 * @return Status code of the request 1938 */ 1939 StatusCode setControl(DifferentialVoltage request); 1940 1941 /** 1942 * Request PID to target position with a differential position 1943 * setpoint. 1944 * <p> 1945 * This control mode will set the motor's position setpoint to the 1946 * position specified by the user. It will also set the motor's 1947 * differential position setpoint to the specified position. 1948 * <ul> 1949 * <li> <b>DifferentialPositionDutyCycle Parameters:</b> 1950 * <ul> 1951 * <li> <b>AveragePosition:</b> Average position to drive toward in 1952 * rotations. 1953 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 1954 * in rotations. 1955 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 1956 * Phoenix Pro), which increases peak power by ~15% 1957 * on supported devices (see {@link SupportsFOC}). 1958 * Set to false to use trapezoidal commutation. 1959 * <p> 1960 * FOC improves motor performance by leveraging 1961 * torque (current) control. However, this may be 1962 * inconvenient for applications that require 1963 * specifying duty cycle or voltage. CTR-Electronics 1964 * has developed a hybrid method that combines the 1965 * performances gains of FOC while still allowing 1966 * applications to provide duty cycle or voltage 1967 * demand. This not to be confused with simple 1968 * sinusoidal control or phase voltage control which 1969 * lacks the performance gains. 1970 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 1971 * controller by selecting the slot. Use the 1972 * configuration api to set the gain values for the 1973 * selected slot before enabling this feature. Slot 1974 * must be within [0,2]. 1975 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 1976 * differential controller by selecting the 1977 * slot. Use the configuration api to set the 1978 * gain values for the selected slot before 1979 * enabling this feature. Slot must be within 1980 * [0,2]. 1981 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 1982 * rotor when output is zero (or within 1983 * deadband). Set to false to use the 1984 * NeutralMode configuration setting 1985 * (default). This flag exists to 1986 * provide the fundamental behavior of 1987 * this control when output is zero, 1988 * which is to provide 0V to the motor. 1989 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 1990 * This allows users to use other limit 1991 * switch sensors connected to robot 1992 * controller. This also allows use of 1993 * active sensors that require external 1994 * power. 1995 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 1996 * This allows users to use other limit 1997 * switch sensors connected to robot 1998 * controller. This also allows use of 1999 * active sensors that require external 2000 * power. 2001 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2002 * switches and the LimitForwardMotion and 2003 * LimitReverseMotion parameters, instead 2004 * allowing motion. 2005 * <p> 2006 * This can be useful on mechanisms such 2007 * as an intake/feeder, where a limit 2008 * switch stops motion while intaking but 2009 * should be ignored when feeding to a 2010 * shooter. 2011 * <p> 2012 * The hardware limit faults and 2013 * Forward/ReverseLimit signals will still 2014 * report the values of the limit switches 2015 * regardless of this parameter. 2016 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2017 * instead allowing motion. 2018 * <p> 2019 * This can be useful when calibrating the 2020 * zero point of a mechanism such as an 2021 * elevator. 2022 * <p> 2023 * The software limit faults will still 2024 * report the values of the software 2025 * limits regardless of this parameter. 2026 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2027 * request until a timesync boundary (requires 2028 * Phoenix Pro and CANivore). This eliminates the 2029 * impact of nondeterministic network delays in 2030 * exchange for a larger but deterministic control 2031 * latency. 2032 * <p> 2033 * This requires setting the ControlTimesyncFreqHz 2034 * config in MotorOutputConfigs. Additionally, when 2035 * this is enabled, the UpdateFreqHz of this 2036 * request should be set to 0 Hz. 2037 * </ul> 2038 * </ul> 2039 * 2040 * @param request Control object to request of the device 2041 * @return Status code of the request 2042 */ 2043 StatusCode setControl(DifferentialPositionDutyCycle request); 2044 2045 /** 2046 * Request PID to target position with a differential position 2047 * setpoint 2048 * <p> 2049 * This control mode will set the motor's position setpoint to the 2050 * position specified by the user. It will also set the motor's 2051 * differential position setpoint to the specified position. 2052 * <ul> 2053 * <li> <b>DifferentialPositionVoltage Parameters:</b> 2054 * <ul> 2055 * <li> <b>AveragePosition:</b> Average position to drive toward in 2056 * rotations. 2057 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2058 * in rotations. 2059 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2060 * Phoenix Pro), which increases peak power by ~15% 2061 * on supported devices (see {@link SupportsFOC}). 2062 * Set to false to use trapezoidal commutation. 2063 * <p> 2064 * FOC improves motor performance by leveraging 2065 * torque (current) control. However, this may be 2066 * inconvenient for applications that require 2067 * specifying duty cycle or voltage. CTR-Electronics 2068 * has developed a hybrid method that combines the 2069 * performances gains of FOC while still allowing 2070 * applications to provide duty cycle or voltage 2071 * demand. This not to be confused with simple 2072 * sinusoidal control or phase voltage control which 2073 * lacks the performance gains. 2074 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2075 * controller by selecting the slot. Use the 2076 * configuration api to set the gain values for the 2077 * selected slot before enabling this feature. Slot 2078 * must be within [0,2]. 2079 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2080 * differential controller by selecting the 2081 * slot. Use the configuration api to set the 2082 * gain values for the selected slot before 2083 * enabling this feature. Slot must be within 2084 * [0,2]. 2085 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2086 * rotor when output is zero (or within 2087 * deadband). Set to false to use the 2088 * NeutralMode configuration setting 2089 * (default). This flag exists to 2090 * provide the fundamental behavior of 2091 * this control when output is zero, 2092 * which is to provide 0V to the motor. 2093 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2094 * This allows users to use other limit 2095 * switch sensors connected to robot 2096 * controller. This also allows use of 2097 * active sensors that require external 2098 * power. 2099 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2100 * This allows users to use other limit 2101 * switch sensors connected to robot 2102 * controller. This also allows use of 2103 * active sensors that require external 2104 * power. 2105 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2106 * switches and the LimitForwardMotion and 2107 * LimitReverseMotion parameters, instead 2108 * allowing motion. 2109 * <p> 2110 * This can be useful on mechanisms such 2111 * as an intake/feeder, where a limit 2112 * switch stops motion while intaking but 2113 * should be ignored when feeding to a 2114 * shooter. 2115 * <p> 2116 * The hardware limit faults and 2117 * Forward/ReverseLimit signals will still 2118 * report the values of the limit switches 2119 * regardless of this parameter. 2120 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2121 * instead allowing motion. 2122 * <p> 2123 * This can be useful when calibrating the 2124 * zero point of a mechanism such as an 2125 * elevator. 2126 * <p> 2127 * The software limit faults will still 2128 * report the values of the software 2129 * limits regardless of this parameter. 2130 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2131 * request until a timesync boundary (requires 2132 * Phoenix Pro and CANivore). This eliminates the 2133 * impact of nondeterministic network delays in 2134 * exchange for a larger but deterministic control 2135 * latency. 2136 * <p> 2137 * This requires setting the ControlTimesyncFreqHz 2138 * config in MotorOutputConfigs. Additionally, when 2139 * this is enabled, the UpdateFreqHz of this 2140 * request should be set to 0 Hz. 2141 * </ul> 2142 * </ul> 2143 * 2144 * @param request Control object to request of the device 2145 * @return Status code of the request 2146 */ 2147 StatusCode setControl(DifferentialPositionVoltage request); 2148 2149 /** 2150 * Request PID to target velocity with a differential position 2151 * setpoint. 2152 * <p> 2153 * This control mode will set the motor's velocity setpoint to the 2154 * velocity specified by the user. It will also set the motor's 2155 * differential position setpoint to the specified position. 2156 * <ul> 2157 * <li> <b>DifferentialVelocityDutyCycle Parameters:</b> 2158 * <ul> 2159 * <li> <b>AverageVelocity:</b> Average velocity to drive toward in 2160 * rotations per second. 2161 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2162 * in rotations. 2163 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2164 * Phoenix Pro), which increases peak power by ~15% 2165 * on supported devices (see {@link SupportsFOC}). 2166 * Set to false to use trapezoidal commutation. 2167 * <p> 2168 * FOC improves motor performance by leveraging 2169 * torque (current) control. However, this may be 2170 * inconvenient for applications that require 2171 * specifying duty cycle or voltage. CTR-Electronics 2172 * has developed a hybrid method that combines the 2173 * performances gains of FOC while still allowing 2174 * applications to provide duty cycle or voltage 2175 * demand. This not to be confused with simple 2176 * sinusoidal control or phase voltage control which 2177 * lacks the performance gains. 2178 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2179 * controller by selecting the slot. Use the 2180 * configuration api to set the gain values for the 2181 * selected slot before enabling this feature. Slot 2182 * must be within [0,2]. 2183 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2184 * differential controller by selecting the 2185 * slot. Use the configuration api to set the 2186 * gain values for the selected slot before 2187 * enabling this feature. Slot must be within 2188 * [0,2]. 2189 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2190 * rotor when output is zero (or within 2191 * deadband). Set to false to use the 2192 * NeutralMode configuration setting 2193 * (default). This flag exists to 2194 * provide the fundamental behavior of 2195 * this control when output is zero, 2196 * which is to provide 0V to the motor. 2197 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2198 * This allows users to use other limit 2199 * switch sensors connected to robot 2200 * controller. This also allows use of 2201 * active sensors that require external 2202 * power. 2203 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2204 * This allows users to use other limit 2205 * switch sensors connected to robot 2206 * controller. This also allows use of 2207 * active sensors that require external 2208 * power. 2209 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2210 * switches and the LimitForwardMotion and 2211 * LimitReverseMotion parameters, instead 2212 * allowing motion. 2213 * <p> 2214 * This can be useful on mechanisms such 2215 * as an intake/feeder, where a limit 2216 * switch stops motion while intaking but 2217 * should be ignored when feeding to a 2218 * shooter. 2219 * <p> 2220 * The hardware limit faults and 2221 * Forward/ReverseLimit signals will still 2222 * report the values of the limit switches 2223 * regardless of this parameter. 2224 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2225 * instead allowing motion. 2226 * <p> 2227 * This can be useful when calibrating the 2228 * zero point of a mechanism such as an 2229 * elevator. 2230 * <p> 2231 * The software limit faults will still 2232 * report the values of the software 2233 * limits regardless of this parameter. 2234 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2235 * request until a timesync boundary (requires 2236 * Phoenix Pro and CANivore). This eliminates the 2237 * impact of nondeterministic network delays in 2238 * exchange for a larger but deterministic control 2239 * latency. 2240 * <p> 2241 * This requires setting the ControlTimesyncFreqHz 2242 * config in MotorOutputConfigs. Additionally, when 2243 * this is enabled, the UpdateFreqHz of this 2244 * request should be set to 0 Hz. 2245 * </ul> 2246 * </ul> 2247 * 2248 * @param request Control object to request of the device 2249 * @return Status code of the request 2250 */ 2251 StatusCode setControl(DifferentialVelocityDutyCycle request); 2252 2253 /** 2254 * Request PID to target velocity with a differential position 2255 * setpoint. 2256 * <p> 2257 * This control mode will set the motor's velocity setpoint to the 2258 * velocity specified by the user. It will also set the motor's 2259 * differential position setpoint to the specified position. 2260 * <ul> 2261 * <li> <b>DifferentialVelocityVoltage Parameters:</b> 2262 * <ul> 2263 * <li> <b>AverageVelocity:</b> Average velocity to drive toward in 2264 * rotations per second. 2265 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2266 * in rotations. 2267 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2268 * Phoenix Pro), which increases peak power by ~15% 2269 * on supported devices (see {@link SupportsFOC}). 2270 * Set to false to use trapezoidal commutation. 2271 * <p> 2272 * FOC improves motor performance by leveraging 2273 * torque (current) control. However, this may be 2274 * inconvenient for applications that require 2275 * specifying duty cycle or voltage. CTR-Electronics 2276 * has developed a hybrid method that combines the 2277 * performances gains of FOC while still allowing 2278 * applications to provide duty cycle or voltage 2279 * demand. This not to be confused with simple 2280 * sinusoidal control or phase voltage control which 2281 * lacks the performance gains. 2282 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2283 * controller by selecting the slot. Use the 2284 * configuration api to set the gain values for the 2285 * selected slot before enabling this feature. Slot 2286 * must be within [0,2]. 2287 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2288 * differential controller by selecting the 2289 * slot. Use the configuration api to set the 2290 * gain values for the selected slot before 2291 * enabling this feature. Slot must be within 2292 * [0,2]. 2293 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2294 * rotor when output is zero (or within 2295 * deadband). Set to false to use the 2296 * NeutralMode configuration setting 2297 * (default). This flag exists to 2298 * provide the fundamental behavior of 2299 * this control when output is zero, 2300 * which is to provide 0V to the motor. 2301 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2302 * This allows users to use other limit 2303 * switch sensors connected to robot 2304 * controller. This also allows use of 2305 * active sensors that require external 2306 * power. 2307 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2308 * This allows users to use other limit 2309 * switch sensors connected to robot 2310 * controller. This also allows use of 2311 * active sensors that require external 2312 * power. 2313 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2314 * switches and the LimitForwardMotion and 2315 * LimitReverseMotion parameters, instead 2316 * allowing motion. 2317 * <p> 2318 * This can be useful on mechanisms such 2319 * as an intake/feeder, where a limit 2320 * switch stops motion while intaking but 2321 * should be ignored when feeding to a 2322 * shooter. 2323 * <p> 2324 * The hardware limit faults and 2325 * Forward/ReverseLimit signals will still 2326 * report the values of the limit switches 2327 * regardless of this parameter. 2328 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2329 * instead allowing motion. 2330 * <p> 2331 * This can be useful when calibrating the 2332 * zero point of a mechanism such as an 2333 * elevator. 2334 * <p> 2335 * The software limit faults will still 2336 * report the values of the software 2337 * limits regardless of this parameter. 2338 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2339 * request until a timesync boundary (requires 2340 * Phoenix Pro and CANivore). This eliminates the 2341 * impact of nondeterministic network delays in 2342 * exchange for a larger but deterministic control 2343 * latency. 2344 * <p> 2345 * This requires setting the ControlTimesyncFreqHz 2346 * config in MotorOutputConfigs. Additionally, when 2347 * this is enabled, the UpdateFreqHz of this 2348 * request should be set to 0 Hz. 2349 * </ul> 2350 * </ul> 2351 * 2352 * @param request Control object to request of the device 2353 * @return Status code of the request 2354 */ 2355 StatusCode setControl(DifferentialVelocityVoltage request); 2356 2357 /** 2358 * Requests Motion Magic® to target a final position using a motion 2359 * profile, and PID to a differential position setpoint. 2360 * <p> 2361 * Motion Magic® produces a motion profile in real-time while 2362 * attempting to honor the Cruise Velocity, Acceleration, and 2363 * (optional) Jerk specified via the Motion Magic® configuration 2364 * values. This control mode does not use the Expo_kV or Expo_kA 2365 * configs. 2366 * <p> 2367 * Target position can be changed on-the-fly and Motion Magic® will do 2368 * its best to adjust the profile. This control mode is duty cycle 2369 * based, so relevant closed-loop gains will use fractional duty cycle 2370 * for the numerator: +1.0 represents full forward output. 2371 * <ul> 2372 * <li> <b>DifferentialMotionMagicDutyCycle Parameters:</b> 2373 * <ul> 2374 * <li> <b>AveragePosition:</b> Average position to drive toward in 2375 * rotations. 2376 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2377 * in rotations. 2378 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2379 * Phoenix Pro), which increases peak power by ~15% 2380 * on supported devices (see {@link SupportsFOC}). 2381 * Set to false to use trapezoidal commutation. 2382 * <p> 2383 * FOC improves motor performance by leveraging 2384 * torque (current) control. However, this may be 2385 * inconvenient for applications that require 2386 * specifying duty cycle or voltage. CTR-Electronics 2387 * has developed a hybrid method that combines the 2388 * performances gains of FOC while still allowing 2389 * applications to provide duty cycle or voltage 2390 * demand. This not to be confused with simple 2391 * sinusoidal control or phase voltage control which 2392 * lacks the performance gains. 2393 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2394 * controller by selecting the slot. Use the 2395 * configuration api to set the gain values for the 2396 * selected slot before enabling this feature. Slot 2397 * must be within [0,2]. 2398 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2399 * differential controller by selecting the 2400 * slot. Use the configuration api to set the 2401 * gain values for the selected slot before 2402 * enabling this feature. Slot must be within 2403 * [0,2]. 2404 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2405 * rotor when output is zero (or within 2406 * deadband). Set to false to use the 2407 * NeutralMode configuration setting 2408 * (default). This flag exists to 2409 * provide the fundamental behavior of 2410 * this control when output is zero, 2411 * which is to provide 0V to the motor. 2412 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2413 * This allows users to use other limit 2414 * switch sensors connected to robot 2415 * controller. This also allows use of 2416 * active sensors that require external 2417 * power. 2418 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2419 * This allows users to use other limit 2420 * switch sensors connected to robot 2421 * controller. This also allows use of 2422 * active sensors that require external 2423 * power. 2424 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2425 * switches and the LimitForwardMotion and 2426 * LimitReverseMotion parameters, instead 2427 * allowing motion. 2428 * <p> 2429 * This can be useful on mechanisms such 2430 * as an intake/feeder, where a limit 2431 * switch stops motion while intaking but 2432 * should be ignored when feeding to a 2433 * shooter. 2434 * <p> 2435 * The hardware limit faults and 2436 * Forward/ReverseLimit signals will still 2437 * report the values of the limit switches 2438 * regardless of this parameter. 2439 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2440 * instead allowing motion. 2441 * <p> 2442 * This can be useful when calibrating the 2443 * zero point of a mechanism such as an 2444 * elevator. 2445 * <p> 2446 * The software limit faults will still 2447 * report the values of the software 2448 * limits regardless of this parameter. 2449 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2450 * request until a timesync boundary (requires 2451 * Phoenix Pro and CANivore). This eliminates the 2452 * impact of nondeterministic network delays in 2453 * exchange for a larger but deterministic control 2454 * latency. 2455 * <p> 2456 * This requires setting the ControlTimesyncFreqHz 2457 * config in MotorOutputConfigs. Additionally, when 2458 * this is enabled, the UpdateFreqHz of this 2459 * request should be set to 0 Hz. 2460 * </ul> 2461 * </ul> 2462 * 2463 * @param request Control object to request of the device 2464 * @return Status code of the request 2465 */ 2466 StatusCode setControl(DifferentialMotionMagicDutyCycle request); 2467 2468 /** 2469 * Requests Motion Magic® to target a final position using a motion 2470 * profile, and PID to a differential position setpoint. 2471 * <p> 2472 * Motion Magic® produces a motion profile in real-time while 2473 * attempting to honor the Cruise Velocity, Acceleration, and 2474 * (optional) Jerk specified via the Motion Magic® configuration 2475 * values. This control mode does not use the Expo_kV or Expo_kA 2476 * configs. 2477 * <p> 2478 * Target position can be changed on-the-fly and Motion Magic® will do 2479 * its best to adjust the profile. This control mode is 2480 * voltage-based, so relevant closed-loop gains will use Volts for the 2481 * numerator. 2482 * <ul> 2483 * <li> <b>DifferentialMotionMagicVoltage Parameters:</b> 2484 * <ul> 2485 * <li> <b>AveragePosition:</b> Average position to drive toward in 2486 * rotations. 2487 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2488 * in rotations. 2489 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2490 * Phoenix Pro), which increases peak power by ~15% 2491 * on supported devices (see {@link SupportsFOC}). 2492 * Set to false to use trapezoidal commutation. 2493 * <p> 2494 * FOC improves motor performance by leveraging 2495 * torque (current) control. However, this may be 2496 * inconvenient for applications that require 2497 * specifying duty cycle or voltage. CTR-Electronics 2498 * has developed a hybrid method that combines the 2499 * performances gains of FOC while still allowing 2500 * applications to provide duty cycle or voltage 2501 * demand. This not to be confused with simple 2502 * sinusoidal control or phase voltage control which 2503 * lacks the performance gains. 2504 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2505 * controller by selecting the slot. Use the 2506 * configuration api to set the gain values for the 2507 * selected slot before enabling this feature. Slot 2508 * must be within [0,2]. 2509 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2510 * differential controller by selecting the 2511 * slot. Use the configuration api to set the 2512 * gain values for the selected slot before 2513 * enabling this feature. Slot must be within 2514 * [0,2]. 2515 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2516 * rotor when output is zero (or within 2517 * deadband). Set to false to use the 2518 * NeutralMode configuration setting 2519 * (default). This flag exists to 2520 * provide the fundamental behavior of 2521 * this control when output is zero, 2522 * which is to provide 0V to the motor. 2523 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2524 * This allows users to use other limit 2525 * switch sensors connected to robot 2526 * controller. This also allows use of 2527 * active sensors that require external 2528 * power. 2529 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2530 * This allows users to use other limit 2531 * switch sensors connected to robot 2532 * controller. This also allows use of 2533 * active sensors that require external 2534 * power. 2535 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2536 * switches and the LimitForwardMotion and 2537 * LimitReverseMotion parameters, instead 2538 * allowing motion. 2539 * <p> 2540 * This can be useful on mechanisms such 2541 * as an intake/feeder, where a limit 2542 * switch stops motion while intaking but 2543 * should be ignored when feeding to a 2544 * shooter. 2545 * <p> 2546 * The hardware limit faults and 2547 * Forward/ReverseLimit signals will still 2548 * report the values of the limit switches 2549 * regardless of this parameter. 2550 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2551 * instead allowing motion. 2552 * <p> 2553 * This can be useful when calibrating the 2554 * zero point of a mechanism such as an 2555 * elevator. 2556 * <p> 2557 * The software limit faults will still 2558 * report the values of the software 2559 * limits regardless of this parameter. 2560 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2561 * request until a timesync boundary (requires 2562 * Phoenix Pro and CANivore). This eliminates the 2563 * impact of nondeterministic network delays in 2564 * exchange for a larger but deterministic control 2565 * latency. 2566 * <p> 2567 * This requires setting the ControlTimesyncFreqHz 2568 * config in MotorOutputConfigs. Additionally, when 2569 * this is enabled, the UpdateFreqHz of this 2570 * request should be set to 0 Hz. 2571 * </ul> 2572 * </ul> 2573 * 2574 * @param request Control object to request of the device 2575 * @return Status code of the request 2576 */ 2577 StatusCode setControl(DifferentialMotionMagicVoltage request); 2578 2579 /** 2580 * Requests Motion Magic® to target a final position using an 2581 * exponential motion profile, and PID to a differential position 2582 * setpoint. 2583 * <p> 2584 * Motion Magic® Expo produces a motion profile in real-time while 2585 * attempting to honor the Cruise Velocity (optional) and the 2586 * mechanism kV and kA, specified via the Motion Magic® configuration 2587 * values. Note that unlike the slot gains, the Expo_kV and Expo_kA 2588 * configs are always in output units of Volts. 2589 * <p> 2590 * Setting Cruise Velocity to 0 will allow the profile to run to the 2591 * max possible velocity based on Expo_kV. This control mode does not 2592 * use the Acceleration or Jerk configs. 2593 * <p> 2594 * Target position can be changed on-the-fly and Motion Magic® will do 2595 * its best to adjust the profile. This control mode is duty cycle 2596 * based, so relevant closed-loop gains will use fractional duty cycle 2597 * for the numerator: +1.0 represents full forward output. 2598 * <ul> 2599 * <li> <b>DifferentialMotionMagicExpoDutyCycle Parameters:</b> 2600 * <ul> 2601 * <li> <b>AveragePosition:</b> Average position to drive toward in 2602 * rotations. 2603 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2604 * in rotations. 2605 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2606 * Phoenix Pro), which increases peak power by ~15% 2607 * on supported devices (see {@link SupportsFOC}). 2608 * Set to false to use trapezoidal commutation. 2609 * <p> 2610 * FOC improves motor performance by leveraging 2611 * torque (current) control. However, this may be 2612 * inconvenient for applications that require 2613 * specifying duty cycle or voltage. CTR-Electronics 2614 * has developed a hybrid method that combines the 2615 * performances gains of FOC while still allowing 2616 * applications to provide duty cycle or voltage 2617 * demand. This not to be confused with simple 2618 * sinusoidal control or phase voltage control which 2619 * lacks the performance gains. 2620 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2621 * controller by selecting the slot. Use the 2622 * configuration api to set the gain values for the 2623 * selected slot before enabling this feature. Slot 2624 * must be within [0,2]. 2625 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2626 * differential controller by selecting the 2627 * slot. Use the configuration api to set the 2628 * gain values for the selected slot before 2629 * enabling this feature. Slot must be within 2630 * [0,2]. 2631 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2632 * rotor when output is zero (or within 2633 * deadband). Set to false to use the 2634 * NeutralMode configuration setting 2635 * (default). This flag exists to 2636 * provide the fundamental behavior of 2637 * this control when output is zero, 2638 * which is to provide 0V to the motor. 2639 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2640 * This allows users to use other limit 2641 * switch sensors connected to robot 2642 * controller. This also allows use of 2643 * active sensors that require external 2644 * power. 2645 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2646 * This allows users to use other limit 2647 * switch sensors connected to robot 2648 * controller. This also allows use of 2649 * active sensors that require external 2650 * power. 2651 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2652 * switches and the LimitForwardMotion and 2653 * LimitReverseMotion parameters, instead 2654 * allowing motion. 2655 * <p> 2656 * This can be useful on mechanisms such 2657 * as an intake/feeder, where a limit 2658 * switch stops motion while intaking but 2659 * should be ignored when feeding to a 2660 * shooter. 2661 * <p> 2662 * The hardware limit faults and 2663 * Forward/ReverseLimit signals will still 2664 * report the values of the limit switches 2665 * regardless of this parameter. 2666 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2667 * instead allowing motion. 2668 * <p> 2669 * This can be useful when calibrating the 2670 * zero point of a mechanism such as an 2671 * elevator. 2672 * <p> 2673 * The software limit faults will still 2674 * report the values of the software 2675 * limits regardless of this parameter. 2676 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2677 * request until a timesync boundary (requires 2678 * Phoenix Pro and CANivore). This eliminates the 2679 * impact of nondeterministic network delays in 2680 * exchange for a larger but deterministic control 2681 * latency. 2682 * <p> 2683 * This requires setting the ControlTimesyncFreqHz 2684 * config in MotorOutputConfigs. Additionally, when 2685 * this is enabled, the UpdateFreqHz of this 2686 * request should be set to 0 Hz. 2687 * </ul> 2688 * </ul> 2689 * 2690 * @param request Control object to request of the device 2691 * @return Status code of the request 2692 */ 2693 StatusCode setControl(DifferentialMotionMagicExpoDutyCycle request); 2694 2695 /** 2696 * Requests Motion Magic® to target a final position using an 2697 * exponential motion profile, and PID to a differential position 2698 * setpoint. 2699 * <p> 2700 * Motion Magic® Expo produces a motion profile in real-time while 2701 * attempting to honor the Cruise Velocity (optional) and the 2702 * mechanism kV and kA, specified via the Motion Magic® configuration 2703 * values. Note that unlike the slot gains, the Expo_kV and Expo_kA 2704 * configs are always in output units of Volts. 2705 * <p> 2706 * Setting Cruise Velocity to 0 will allow the profile to run to the 2707 * max possible velocity based on Expo_kV. This control mode does not 2708 * use the Acceleration or Jerk configs. 2709 * <p> 2710 * Target position can be changed on-the-fly and Motion Magic® will do 2711 * its best to adjust the profile. This control mode is 2712 * voltage-based, so relevant closed-loop gains will use Volts for the 2713 * numerator. 2714 * <ul> 2715 * <li> <b>DifferentialMotionMagicExpoVoltage Parameters:</b> 2716 * <ul> 2717 * <li> <b>AveragePosition:</b> Average position to drive toward in 2718 * rotations. 2719 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2720 * in rotations. 2721 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2722 * Phoenix Pro), which increases peak power by ~15% 2723 * on supported devices (see {@link SupportsFOC}). 2724 * Set to false to use trapezoidal commutation. 2725 * <p> 2726 * FOC improves motor performance by leveraging 2727 * torque (current) control. However, this may be 2728 * inconvenient for applications that require 2729 * specifying duty cycle or voltage. CTR-Electronics 2730 * has developed a hybrid method that combines the 2731 * performances gains of FOC while still allowing 2732 * applications to provide duty cycle or voltage 2733 * demand. This not to be confused with simple 2734 * sinusoidal control or phase voltage control which 2735 * lacks the performance gains. 2736 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2737 * controller by selecting the slot. Use the 2738 * configuration api to set the gain values for the 2739 * selected slot before enabling this feature. Slot 2740 * must be within [0,2]. 2741 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2742 * differential controller by selecting the 2743 * slot. Use the configuration api to set the 2744 * gain values for the selected slot before 2745 * enabling this feature. Slot must be within 2746 * [0,2]. 2747 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2748 * rotor when output is zero (or within 2749 * deadband). Set to false to use the 2750 * NeutralMode configuration setting 2751 * (default). This flag exists to 2752 * provide the fundamental behavior of 2753 * this control when output is zero, 2754 * which is to provide 0V to the motor. 2755 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2756 * This allows users to use other limit 2757 * switch sensors connected to robot 2758 * controller. This also allows use of 2759 * active sensors that require external 2760 * power. 2761 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2762 * This allows users to use other limit 2763 * switch sensors connected to robot 2764 * controller. This also allows use of 2765 * active sensors that require external 2766 * power. 2767 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2768 * switches and the LimitForwardMotion and 2769 * LimitReverseMotion parameters, instead 2770 * allowing motion. 2771 * <p> 2772 * This can be useful on mechanisms such 2773 * as an intake/feeder, where a limit 2774 * switch stops motion while intaking but 2775 * should be ignored when feeding to a 2776 * shooter. 2777 * <p> 2778 * The hardware limit faults and 2779 * Forward/ReverseLimit signals will still 2780 * report the values of the limit switches 2781 * regardless of this parameter. 2782 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2783 * instead allowing motion. 2784 * <p> 2785 * This can be useful when calibrating the 2786 * zero point of a mechanism such as an 2787 * elevator. 2788 * <p> 2789 * The software limit faults will still 2790 * report the values of the software 2791 * limits regardless of this parameter. 2792 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2793 * request until a timesync boundary (requires 2794 * Phoenix Pro and CANivore). This eliminates the 2795 * impact of nondeterministic network delays in 2796 * exchange for a larger but deterministic control 2797 * latency. 2798 * <p> 2799 * This requires setting the ControlTimesyncFreqHz 2800 * config in MotorOutputConfigs. Additionally, when 2801 * this is enabled, the UpdateFreqHz of this 2802 * request should be set to 0 Hz. 2803 * </ul> 2804 * </ul> 2805 * 2806 * @param request Control object to request of the device 2807 * @return Status code of the request 2808 */ 2809 StatusCode setControl(DifferentialMotionMagicExpoVoltage request); 2810 2811 /** 2812 * Requests Motion Magic® to target a final velocity using a motion 2813 * profile, and PID to a differential position setpoint. This allows 2814 * smooth transitions between velocity set points. 2815 * <p> 2816 * Motion Magic® Velocity produces a motion profile in real-time while 2817 * attempting to honor the specified Acceleration and (optional) Jerk. 2818 * This control mode does not use the CruiseVelocity, Expo_kV, or 2819 * Expo_kA configs. 2820 * <p> 2821 * Acceleration and jerk are specified in the Motion Magic® persistent 2822 * configuration values. If Jerk is set to zero, Motion Magic® will 2823 * produce a trapezoidal acceleration profile. 2824 * <p> 2825 * Target velocity can also be changed on-the-fly and Motion Magic® 2826 * will do its best to adjust the profile. This control mode is duty 2827 * cycle based, so relevant closed-loop gains will use fractional duty 2828 * cycle for the numerator: +1.0 represents full forward output. 2829 * <ul> 2830 * <li> <b>DifferentialMotionMagicVelocityDutyCycle Parameters:</b> 2831 * <ul> 2832 * <li> <b>AverageVelocity:</b> Average velocity to drive toward in 2833 * rotations per second. 2834 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2835 * in rotations. 2836 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2837 * Phoenix Pro), which increases peak power by ~15% 2838 * on supported devices (see {@link SupportsFOC}). 2839 * Set to false to use trapezoidal commutation. 2840 * <p> 2841 * FOC improves motor performance by leveraging 2842 * torque (current) control. However, this may be 2843 * inconvenient for applications that require 2844 * specifying duty cycle or voltage. CTR-Electronics 2845 * has developed a hybrid method that combines the 2846 * performances gains of FOC while still allowing 2847 * applications to provide duty cycle or voltage 2848 * demand. This not to be confused with simple 2849 * sinusoidal control or phase voltage control which 2850 * lacks the performance gains. 2851 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2852 * controller by selecting the slot. Use the 2853 * configuration api to set the gain values for the 2854 * selected slot before enabling this feature. Slot 2855 * must be within [0,2]. 2856 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2857 * differential controller by selecting the 2858 * slot. Use the configuration api to set the 2859 * gain values for the selected slot before 2860 * enabling this feature. Slot must be within 2861 * [0,2]. 2862 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2863 * rotor when output is zero (or within 2864 * deadband). Set to false to use the 2865 * NeutralMode configuration setting 2866 * (default). This flag exists to 2867 * provide the fundamental behavior of 2868 * this control when output is zero, 2869 * which is to provide 0V to the motor. 2870 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2871 * This allows users to use other limit 2872 * switch sensors connected to robot 2873 * controller. This also allows use of 2874 * active sensors that require external 2875 * power. 2876 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2877 * This allows users to use other limit 2878 * switch sensors connected to robot 2879 * controller. This also allows use of 2880 * active sensors that require external 2881 * power. 2882 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2883 * switches and the LimitForwardMotion and 2884 * LimitReverseMotion parameters, instead 2885 * allowing motion. 2886 * <p> 2887 * This can be useful on mechanisms such 2888 * as an intake/feeder, where a limit 2889 * switch stops motion while intaking but 2890 * should be ignored when feeding to a 2891 * shooter. 2892 * <p> 2893 * The hardware limit faults and 2894 * Forward/ReverseLimit signals will still 2895 * report the values of the limit switches 2896 * regardless of this parameter. 2897 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 2898 * instead allowing motion. 2899 * <p> 2900 * This can be useful when calibrating the 2901 * zero point of a mechanism such as an 2902 * elevator. 2903 * <p> 2904 * The software limit faults will still 2905 * report the values of the software 2906 * limits regardless of this parameter. 2907 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 2908 * request until a timesync boundary (requires 2909 * Phoenix Pro and CANivore). This eliminates the 2910 * impact of nondeterministic network delays in 2911 * exchange for a larger but deterministic control 2912 * latency. 2913 * <p> 2914 * This requires setting the ControlTimesyncFreqHz 2915 * config in MotorOutputConfigs. Additionally, when 2916 * this is enabled, the UpdateFreqHz of this 2917 * request should be set to 0 Hz. 2918 * </ul> 2919 * </ul> 2920 * 2921 * @param request Control object to request of the device 2922 * @return Status code of the request 2923 */ 2924 StatusCode setControl(DifferentialMotionMagicVelocityDutyCycle request); 2925 2926 /** 2927 * Requests Motion Magic® to target a final velocity using a motion 2928 * profile, and PID to a differential position setpoint. This allows 2929 * smooth transitions between velocity set points. 2930 * <p> 2931 * Motion Magic® Velocity produces a motion profile in real-time while 2932 * attempting to honor the specified Acceleration and (optional) Jerk. 2933 * This control mode does not use the CruiseVelocity, Expo_kV, or 2934 * Expo_kA configs. 2935 * <p> 2936 * Acceleration and jerk are specified in the Motion Magic® persistent 2937 * configuration values. If Jerk is set to zero, Motion Magic® will 2938 * produce a trapezoidal acceleration profile. 2939 * <p> 2940 * Target velocity can also be changed on-the-fly and Motion Magic® 2941 * will do its best to adjust the profile. This control mode is 2942 * voltage-based, so relevant closed-loop gains will use Volts for the 2943 * numerator. 2944 * <ul> 2945 * <li> <b>DifferentialMotionMagicVelocityVoltage Parameters:</b> 2946 * <ul> 2947 * <li> <b>AverageVelocity:</b> Average velocity to drive toward in 2948 * rotations per second. 2949 * <li> <b>DifferentialPosition:</b> Differential position to drive toward 2950 * in rotations. 2951 * <li> <b>EnableFOC:</b> Set to true to use FOC commutation (requires 2952 * Phoenix Pro), which increases peak power by ~15% 2953 * on supported devices (see {@link SupportsFOC}). 2954 * Set to false to use trapezoidal commutation. 2955 * <p> 2956 * FOC improves motor performance by leveraging 2957 * torque (current) control. However, this may be 2958 * inconvenient for applications that require 2959 * specifying duty cycle or voltage. CTR-Electronics 2960 * has developed a hybrid method that combines the 2961 * performances gains of FOC while still allowing 2962 * applications to provide duty cycle or voltage 2963 * demand. This not to be confused with simple 2964 * sinusoidal control or phase voltage control which 2965 * lacks the performance gains. 2966 * <li> <b>AverageSlot:</b> Select which gains are applied to the average 2967 * controller by selecting the slot. Use the 2968 * configuration api to set the gain values for the 2969 * selected slot before enabling this feature. Slot 2970 * must be within [0,2]. 2971 * <li> <b>DifferentialSlot:</b> Select which gains are applied to the 2972 * differential controller by selecting the 2973 * slot. Use the configuration api to set the 2974 * gain values for the selected slot before 2975 * enabling this feature. Slot must be within 2976 * [0,2]. 2977 * <li> <b>OverrideBrakeDurNeutral:</b> Set to true to static-brake the 2978 * rotor when output is zero (or within 2979 * deadband). Set to false to use the 2980 * NeutralMode configuration setting 2981 * (default). This flag exists to 2982 * provide the fundamental behavior of 2983 * this control when output is zero, 2984 * which is to provide 0V to the motor. 2985 * <li> <b>LimitForwardMotion:</b> Set to true to force forward limiting. 2986 * This allows users to use other limit 2987 * switch sensors connected to robot 2988 * controller. This also allows use of 2989 * active sensors that require external 2990 * power. 2991 * <li> <b>LimitReverseMotion:</b> Set to true to force reverse limiting. 2992 * This allows users to use other limit 2993 * switch sensors connected to robot 2994 * controller. This also allows use of 2995 * active sensors that require external 2996 * power. 2997 * <li> <b>IgnoreHardwareLimits:</b> Set to true to ignore hardware limit 2998 * switches and the LimitForwardMotion and 2999 * LimitReverseMotion parameters, instead 3000 * allowing motion. 3001 * <p> 3002 * This can be useful on mechanisms such 3003 * as an intake/feeder, where a limit 3004 * switch stops motion while intaking but 3005 * should be ignored when feeding to a 3006 * shooter. 3007 * <p> 3008 * The hardware limit faults and 3009 * Forward/ReverseLimit signals will still 3010 * report the values of the limit switches 3011 * regardless of this parameter. 3012 * <li> <b>IgnoreSoftwareLimits:</b> Set to true to ignore software limits, 3013 * instead allowing motion. 3014 * <p> 3015 * This can be useful when calibrating the 3016 * zero point of a mechanism such as an 3017 * elevator. 3018 * <p> 3019 * The software limit faults will still 3020 * report the values of the software 3021 * limits regardless of this parameter. 3022 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 3023 * request until a timesync boundary (requires 3024 * Phoenix Pro and CANivore). This eliminates the 3025 * impact of nondeterministic network delays in 3026 * exchange for a larger but deterministic control 3027 * latency. 3028 * <p> 3029 * This requires setting the ControlTimesyncFreqHz 3030 * config in MotorOutputConfigs. Additionally, when 3031 * this is enabled, the UpdateFreqHz of this 3032 * request should be set to 0 Hz. 3033 * </ul> 3034 * </ul> 3035 * 3036 * @param request Control object to request of the device 3037 * @return Status code of the request 3038 */ 3039 StatusCode setControl(DifferentialMotionMagicVelocityVoltage request); 3040 3041 /** 3042 * Follow the motor output of another Talon. 3043 * <p> 3044 * The follower will atomically change its output type when it 3045 * receives the leader's latest output status signal (DutyCycle, 3046 * MotorVoltage, TorqueCurrent). If Talon is in torque control, the 3047 * torque is copied - which will increase the total torque applied. If 3048 * Talon is in duty cycle output control, the duty cycle is matched. 3049 * If Talon is in voltage output control, the motor voltage is 3050 * matched. Motor direction either matches the leader's configured 3051 * direction or opposes it based on the MotorAlignment. 3052 * <p> 3053 * The leader must ensure the status signal corresponding to its 3054 * control output type (DutyCycle, MotorVoltage, TorqueCurrent) is 3055 * enabled. The update rate of the status signal determines the update 3056 * rate of the follower's output and should be no slower than 20 Hz. 3057 * <ul> 3058 * <li> <b>Follower Parameters:</b> 3059 * <ul> 3060 * <li> <b>LeaderID:</b> Device ID of the leader to follow. 3061 * <li> <b>MotorAlignment:</b> Set to Aligned for motor invert to match the 3062 * leader's configured Invert - which is typical 3063 * when leader and follower are mechanically 3064 * linked and spin in the same direction. Set 3065 * to Opposed for motor invert to oppose the 3066 * leader's configured Invert - this is typical 3067 * where the leader and follower mechanically 3068 * spin in opposite directions. 3069 * </ul> 3070 * </ul> 3071 * 3072 * @param request Control object to request of the device 3073 * @return Status code of the request 3074 */ 3075 StatusCode setControl(Follower request); 3076 3077 /** 3078 * Follow the motor output of another Talon while ignoring the 3079 * leader's invert setting. 3080 * <p> 3081 * The follower will atomically change its output type when it 3082 * receives the leader's latest output status signal (DutyCycle, 3083 * MotorVoltage, TorqueCurrent). If Talon is in torque control, the 3084 * torque is copied - which will increase the total torque applied. If 3085 * Talon is in duty cycle output control, the duty cycle is matched. 3086 * If Talon is in voltage output control, the motor voltage is 3087 * matched. Motor direction is strictly determined by the configured 3088 * invert and not the leader. If you want motor direction to match or 3089 * oppose the leader, use Follower instead. 3090 * <p> 3091 * The leader must ensure the status signal corresponding to its 3092 * control output type (DutyCycle, MotorVoltage, TorqueCurrent) is 3093 * enabled. The update rate of the status signal determines the update 3094 * rate of the follower's output and should be no slower than 20 Hz. 3095 * <ul> 3096 * <li> <b>StrictFollower Parameters:</b> 3097 * <ul> 3098 * <li> <b>LeaderID:</b> Device ID of the leader to follow. 3099 * </ul> 3100 * </ul> 3101 * 3102 * @param request Control object to request of the device 3103 * @return Status code of the request 3104 */ 3105 StatusCode setControl(StrictFollower request); 3106 3107 /** 3108 * Follow the differential motor output of another Talon. 3109 * <p> 3110 * If Talon is in torque control, the differential torque is copied - 3111 * which will increase the total torque applied. If Talon is in duty 3112 * cycle output control, the differential duty cycle is matched. If 3113 * Talon is in voltage output control, the differential motor voltage 3114 * is matched. Motor direction either matches leader's configured 3115 * direction or opposes it based on the MotorAlignment. 3116 * <p> 3117 * The leader must enable its DifferentialOutput status signal. The 3118 * update rate of the status signal determines the update rate of the 3119 * follower's output and should be no slower than 20 Hz. 3120 * <ul> 3121 * <li> <b>DifferentialFollower Parameters:</b> 3122 * <ul> 3123 * <li> <b>LeaderID:</b> Device ID of the differential leader to follow. 3124 * <li> <b>MotorAlignment:</b> Set to Aligned for motor invert to match the 3125 * leader's configured Invert - which is typical 3126 * when leader and follower are mechanically 3127 * linked and spin in the same direction. Set 3128 * to Opposed for motor invert to oppose the 3129 * leader's configured Invert - this is typical 3130 * where the leader and follower mechanically 3131 * spin in opposite directions. 3132 * </ul> 3133 * </ul> 3134 * 3135 * @param request Control object to request of the device 3136 * @return Status code of the request 3137 */ 3138 StatusCode setControl(DifferentialFollower request); 3139 3140 /** 3141 * Follow the differential motor output of another Talon while 3142 * ignoring the leader's invert setting. 3143 * <p> 3144 * If Talon is in torque control, the differential torque is copied - 3145 * which will increase the total torque applied. If Talon is in duty 3146 * cycle output control, the differential duty cycle is matched. If 3147 * Talon is in voltage output control, the differential motor voltage 3148 * is matched. Motor direction is strictly determined by the 3149 * configured invert and not the leader. If you want motor direction 3150 * to match or oppose the leader, use DifferentialFollower instead. 3151 * <p> 3152 * The leader must enable its DifferentialOutput status signal. The 3153 * update rate of the status signal determines the update rate of the 3154 * follower's output and should be no slower than 20 Hz. 3155 * <ul> 3156 * <li> <b>DifferentialStrictFollower Parameters:</b> 3157 * <ul> 3158 * <li> <b>LeaderID:</b> Device ID of the differential leader to follow. 3159 * </ul> 3160 * </ul> 3161 * 3162 * @param request Control object to request of the device 3163 * @return Status code of the request 3164 */ 3165 StatusCode setControl(DifferentialStrictFollower request); 3166 3167 /** 3168 * Applies full neutral-brake by shorting motor leads together. 3169 * <ul> 3170 * <li> <b>StaticBrake Parameters:</b> 3171 * <ul> 3172 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 3173 * request until a timesync boundary (requires 3174 * Phoenix Pro and CANivore). This eliminates the 3175 * impact of nondeterministic network delays in 3176 * exchange for a larger but deterministic control 3177 * latency. 3178 * <p> 3179 * This requires setting the ControlTimesyncFreqHz 3180 * config in MotorOutputConfigs. Additionally, when 3181 * this is enabled, the UpdateFreqHz of this 3182 * request should be set to 0 Hz. 3183 * </ul> 3184 * </ul> 3185 * 3186 * @param request Control object to request of the device 3187 * @return Status code of the request 3188 */ 3189 StatusCode setControl(StaticBrake request); 3190 3191 /** 3192 * Request neutral output of actuator. The applied brake type is 3193 * determined by the NeutralMode configuration. 3194 * <ul> 3195 * <li> <b>NeutralOut Parameters:</b> 3196 * <ul> 3197 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 3198 * request until a timesync boundary (requires 3199 * Phoenix Pro and CANivore). This eliminates the 3200 * impact of nondeterministic network delays in 3201 * exchange for a larger but deterministic control 3202 * latency. 3203 * <p> 3204 * This requires setting the ControlTimesyncFreqHz 3205 * config in MotorOutputConfigs. Additionally, when 3206 * this is enabled, the UpdateFreqHz of this 3207 * request should be set to 0 Hz. 3208 * </ul> 3209 * </ul> 3210 * 3211 * @param request Control object to request of the device 3212 * @return Status code of the request 3213 */ 3214 StatusCode setControl(NeutralOut request); 3215 3216 /** 3217 * Request coast neutral output of actuator. The bridge is disabled 3218 * and the rotor is allowed to coast. 3219 * <ul> 3220 * <li> <b>CoastOut Parameters:</b> 3221 * <ul> 3222 * <li> <b>UseTimesync:</b> Set to true to delay applying this control 3223 * request until a timesync boundary (requires 3224 * Phoenix Pro and CANivore). This eliminates the 3225 * impact of nondeterministic network delays in 3226 * exchange for a larger but deterministic control 3227 * latency. 3228 * <p> 3229 * This requires setting the ControlTimesyncFreqHz 3230 * config in MotorOutputConfigs. Additionally, when 3231 * this is enabled, the UpdateFreqHz of this 3232 * request should be set to 0 Hz. 3233 * </ul> 3234 * </ul> 3235 * 3236 * @param request Control object to request of the device 3237 * @return Status code of the request 3238 */ 3239 StatusCode setControl(CoastOut request); 3240 3241 /** 3242 * Differential control with duty cycle average target and position 3243 * difference target. 3244 * <ul> 3245 * <li> <b>Diff_DutyCycleOut_Position Parameters:</b> 3246 * <ul> 3247 * <li> <b>AverageRequest:</b> Average DutyCycleOut request of the 3248 * mechanism. 3249 * <li> <b>DifferentialRequest:</b> Differential PositionDutyCycle request 3250 * of the mechanism. 3251 * </ul> 3252 * </ul> 3253 * 3254 * @param request Control object to request of the device 3255 * @return Status code of the request 3256 */ 3257 StatusCode setControl(Diff_DutyCycleOut_Position request); 3258 3259 /** 3260 * Differential control with position average target and position 3261 * difference target using duty cycle control. 3262 * <ul> 3263 * <li> <b>Diff_PositionDutyCycle_Position Parameters:</b> 3264 * <ul> 3265 * <li> <b>AverageRequest:</b> Average PositionDutyCycle request of the 3266 * mechanism. 3267 * <li> <b>DifferentialRequest:</b> Differential PositionDutyCycle request 3268 * of the mechanism. 3269 * </ul> 3270 * </ul> 3271 * 3272 * @param request Control object to request of the device 3273 * @return Status code of the request 3274 */ 3275 StatusCode setControl(Diff_PositionDutyCycle_Position request); 3276 3277 /** 3278 * Differential control with velocity average target and position 3279 * difference target using duty cycle control. 3280 * <ul> 3281 * <li> <b>Diff_VelocityDutyCycle_Position Parameters:</b> 3282 * <ul> 3283 * <li> <b>AverageRequest:</b> Average VelocityDutyCYcle request of the 3284 * mechanism. 3285 * <li> <b>DifferentialRequest:</b> Differential PositionDutyCycle request 3286 * of the mechanism. 3287 * </ul> 3288 * </ul> 3289 * 3290 * @param request Control object to request of the device 3291 * @return Status code of the request 3292 */ 3293 StatusCode setControl(Diff_VelocityDutyCycle_Position request); 3294 3295 /** 3296 * Differential control with Motion Magic® average target and position 3297 * difference target using duty cycle control. 3298 * <ul> 3299 * <li> <b>Diff_MotionMagicDutyCycle_Position Parameters:</b> 3300 * <ul> 3301 * <li> <b>AverageRequest:</b> Average MotionMagicDutyCycle request of the 3302 * mechanism. 3303 * <li> <b>DifferentialRequest:</b> Differential PositionDutyCycle request 3304 * of the mechanism. 3305 * </ul> 3306 * </ul> 3307 * 3308 * @param request Control object to request of the device 3309 * @return Status code of the request 3310 */ 3311 StatusCode setControl(Diff_MotionMagicDutyCycle_Position request); 3312 3313 /** 3314 * Differential control with Motion Magic® Expo average target and 3315 * position difference target using duty cycle control. 3316 * <ul> 3317 * <li> <b>Diff_MotionMagicExpoDutyCycle_Position Parameters:</b> 3318 * <ul> 3319 * <li> <b>AverageRequest:</b> Average MotionMagicExpoDutyCycle request of 3320 * the mechanism. 3321 * <li> <b>DifferentialRequest:</b> Differential PositionDutyCycle request 3322 * of the mechanism. 3323 * </ul> 3324 * </ul> 3325 * 3326 * @param request Control object to request of the device 3327 * @return Status code of the request 3328 */ 3329 StatusCode setControl(Diff_MotionMagicExpoDutyCycle_Position request); 3330 3331 /** 3332 * Differential control with Motion Magic® Velocity average target and 3333 * position difference target using duty cycle control. 3334 * <ul> 3335 * <li> <b>Diff_MotionMagicVelocityDutyCycle_Position Parameters:</b> 3336 * <ul> 3337 * <li> <b>AverageRequest:</b> Average MotionMagicVelocityDutyCycle request 3338 * of the mechanism. 3339 * <li> <b>DifferentialRequest:</b> Differential PositionDutyCycle request 3340 * of the mechanism. 3341 * </ul> 3342 * </ul> 3343 * 3344 * @param request Control object to request of the device 3345 * @return Status code of the request 3346 */ 3347 StatusCode setControl(Diff_MotionMagicVelocityDutyCycle_Position request); 3348 3349 /** 3350 * Differential control with duty cycle average target and velocity 3351 * difference target. 3352 * <ul> 3353 * <li> <b>Diff_DutyCycleOut_Velocity Parameters:</b> 3354 * <ul> 3355 * <li> <b>AverageRequest:</b> Average DutyCycleOut request of the 3356 * mechanism. 3357 * <li> <b>DifferentialRequest:</b> Differential VelocityDutyCycle request 3358 * of the mechanism. 3359 * </ul> 3360 * </ul> 3361 * 3362 * @param request Control object to request of the device 3363 * @return Status code of the request 3364 */ 3365 StatusCode setControl(Diff_DutyCycleOut_Velocity request); 3366 3367 /** 3368 * Differential control with position average target and velocity 3369 * difference target using duty cycle control. 3370 * <ul> 3371 * <li> <b>Diff_PositionDutyCycle_Velocity Parameters:</b> 3372 * <ul> 3373 * <li> <b>AverageRequest:</b> Average PositionDutyCycle request of the 3374 * mechanism. 3375 * <li> <b>DifferentialRequest:</b> Differential VelocityDutyCycle request 3376 * of the mechanism. 3377 * </ul> 3378 * </ul> 3379 * 3380 * @param request Control object to request of the device 3381 * @return Status code of the request 3382 */ 3383 StatusCode setControl(Diff_PositionDutyCycle_Velocity request); 3384 3385 /** 3386 * Differential control with velocity average target and velocity 3387 * difference target using duty cycle control. 3388 * <ul> 3389 * <li> <b>Diff_VelocityDutyCycle_Velocity Parameters:</b> 3390 * <ul> 3391 * <li> <b>AverageRequest:</b> Average VelocityDutyCycle request of the 3392 * mechanism. 3393 * <li> <b>DifferentialRequest:</b> Differential VelocityDutyCycle request 3394 * of the mechanism. 3395 * </ul> 3396 * </ul> 3397 * 3398 * @param request Control object to request of the device 3399 * @return Status code of the request 3400 */ 3401 StatusCode setControl(Diff_VelocityDutyCycle_Velocity request); 3402 3403 /** 3404 * Differential control with Motion Magic® average target and velocity 3405 * difference target using duty cycle control. 3406 * <ul> 3407 * <li> <b>Diff_MotionMagicDutyCycle_Velocity Parameters:</b> 3408 * <ul> 3409 * <li> <b>AverageRequest:</b> Average MotionMagicDutyCycle request of the 3410 * mechanism. 3411 * <li> <b>DifferentialRequest:</b> Differential VelocityDutyCycle request 3412 * of the mechanism. 3413 * </ul> 3414 * </ul> 3415 * 3416 * @param request Control object to request of the device 3417 * @return Status code of the request 3418 */ 3419 StatusCode setControl(Diff_MotionMagicDutyCycle_Velocity request); 3420 3421 /** 3422 * Differential control with Motion Magic® Expo average target and 3423 * velocity difference target using duty cycle control. 3424 * <ul> 3425 * <li> <b>Diff_MotionMagicExpoDutyCycle_Velocity Parameters:</b> 3426 * <ul> 3427 * <li> <b>AverageRequest:</b> Average MotionMagicExpoDutyCycle request of 3428 * the mechanism. 3429 * <li> <b>DifferentialRequest:</b> Differential VelocityDutyCycle request 3430 * of the mechanism. 3431 * </ul> 3432 * </ul> 3433 * 3434 * @param request Control object to request of the device 3435 * @return Status code of the request 3436 */ 3437 StatusCode setControl(Diff_MotionMagicExpoDutyCycle_Velocity request); 3438 3439 /** 3440 * Differential control with Motion Magic® Velocity average target and 3441 * velocity difference target using duty cycle control. 3442 * <ul> 3443 * <li> <b>Diff_MotionMagicVelocityDutyCycle_Velocity Parameters:</b> 3444 * <ul> 3445 * <li> <b>AverageRequest:</b> Average MotionMagicVelocityDutyCycle request 3446 * of the mechanism. 3447 * <li> <b>DifferentialRequest:</b> Differential VelocityDutyCycle request 3448 * of the mechanism. 3449 * </ul> 3450 * </ul> 3451 * 3452 * @param request Control object to request of the device 3453 * @return Status code of the request 3454 */ 3455 StatusCode setControl(Diff_MotionMagicVelocityDutyCycle_Velocity request); 3456 3457 /** 3458 * Differential control with duty cycle average target and duty cycle 3459 * difference target. 3460 * <ul> 3461 * <li> <b>Diff_DutyCycleOut_Open Parameters:</b> 3462 * <ul> 3463 * <li> <b>AverageRequest:</b> Average DutyCycleOut request of the 3464 * mechanism. 3465 * <li> <b>DifferentialRequest:</b> Differential DutyCycleOut request of the 3466 * mechanism. 3467 * </ul> 3468 * </ul> 3469 * 3470 * @param request Control object to request of the device 3471 * @return Status code of the request 3472 */ 3473 StatusCode setControl(Diff_DutyCycleOut_Open request); 3474 3475 /** 3476 * Differential control with position average target and duty cycle 3477 * difference target. 3478 * <ul> 3479 * <li> <b>Diff_PositionDutyCycle_Open Parameters:</b> 3480 * <ul> 3481 * <li> <b>AverageRequest:</b> Average PositionDutyCycle request of the 3482 * mechanism. 3483 * <li> <b>DifferentialRequest:</b> Differential DutyCycleOut request of the 3484 * mechanism. 3485 * </ul> 3486 * </ul> 3487 * 3488 * @param request Control object to request of the device 3489 * @return Status code of the request 3490 */ 3491 StatusCode setControl(Diff_PositionDutyCycle_Open request); 3492 3493 /** 3494 * Differential control with velocity average target and duty cycle 3495 * difference target. 3496 * <ul> 3497 * <li> <b>Diff_VelocityDutyCycle_Open Parameters:</b> 3498 * <ul> 3499 * <li> <b>AverageRequest:</b> Average VelocityDutyCYcle request of the 3500 * mechanism. 3501 * <li> <b>DifferentialRequest:</b> Differential DutyCycleOut request of the 3502 * mechanism. 3503 * </ul> 3504 * </ul> 3505 * 3506 * @param request Control object to request of the device 3507 * @return Status code of the request 3508 */ 3509 StatusCode setControl(Diff_VelocityDutyCycle_Open request); 3510 3511 /** 3512 * Differential control with Motion Magic® average target and duty 3513 * cycle difference target. 3514 * <ul> 3515 * <li> <b>Diff_MotionMagicDutyCycle_Open Parameters:</b> 3516 * <ul> 3517 * <li> <b>AverageRequest:</b> Average MotionMagicDutyCycle request of the 3518 * mechanism. 3519 * <li> <b>DifferentialRequest:</b> Differential DutyCycleOut request of the 3520 * mechanism. 3521 * </ul> 3522 * </ul> 3523 * 3524 * @param request Control object to request of the device 3525 * @return Status code of the request 3526 */ 3527 StatusCode setControl(Diff_MotionMagicDutyCycle_Open request); 3528 3529 /** 3530 * Differential control with Motion Magic® Expo average target and 3531 * duty cycle difference target. 3532 * <ul> 3533 * <li> <b>Diff_MotionMagicExpoDutyCycle_Open Parameters:</b> 3534 * <ul> 3535 * <li> <b>AverageRequest:</b> Average MotionMagicExpoDutyCycle request of 3536 * the mechanism. 3537 * <li> <b>DifferentialRequest:</b> Differential DutyCycleOut request of the 3538 * mechanism. 3539 * </ul> 3540 * </ul> 3541 * 3542 * @param request Control object to request of the device 3543 * @return Status code of the request 3544 */ 3545 StatusCode setControl(Diff_MotionMagicExpoDutyCycle_Open request); 3546 3547 /** 3548 * Differential control with Motion Magic® Velocity average target and 3549 * duty cycle difference target. 3550 * <ul> 3551 * <li> <b>Diff_MotionMagicVelocityDutyCycle_Open Parameters:</b> 3552 * <ul> 3553 * <li> <b>AverageRequest:</b> Average MotionMagicVelocityDutyCycle request 3554 * of the mechanism. 3555 * <li> <b>DifferentialRequest:</b> Differential DutyCycleOut request of the 3556 * mechanism. 3557 * </ul> 3558 * </ul> 3559 * 3560 * @param request Control object to request of the device 3561 * @return Status code of the request 3562 */ 3563 StatusCode setControl(Diff_MotionMagicVelocityDutyCycle_Open request); 3564 3565 /** 3566 * Differential control with voltage average target and position 3567 * difference target. 3568 * <ul> 3569 * <li> <b>Diff_VoltageOut_Position Parameters:</b> 3570 * <ul> 3571 * <li> <b>AverageRequest:</b> Average VoltageOut request of the mechanism. 3572 * <li> <b>DifferentialRequest:</b> Differential PositionVoltage request of 3573 * the mechanism. 3574 * </ul> 3575 * </ul> 3576 * 3577 * @param request Control object to request of the device 3578 * @return Status code of the request 3579 */ 3580 StatusCode setControl(Diff_VoltageOut_Position request); 3581 3582 /** 3583 * Differential control with position average target and position 3584 * difference target using voltage control. 3585 * <ul> 3586 * <li> <b>Diff_PositionVoltage_Position Parameters:</b> 3587 * <ul> 3588 * <li> <b>AverageRequest:</b> Average PositionVoltage request of the 3589 * mechanism. 3590 * <li> <b>DifferentialRequest:</b> Differential PositionVoltage request of 3591 * the mechanism. 3592 * </ul> 3593 * </ul> 3594 * 3595 * @param request Control object to request of the device 3596 * @return Status code of the request 3597 */ 3598 StatusCode setControl(Diff_PositionVoltage_Position request); 3599 3600 /** 3601 * Differential control with velocity average target and position 3602 * difference target using voltage control. 3603 * <ul> 3604 * <li> <b>Diff_VelocityVoltage_Position Parameters:</b> 3605 * <ul> 3606 * <li> <b>AverageRequest:</b> Average VelocityVoltage request of the 3607 * mechanism. 3608 * <li> <b>DifferentialRequest:</b> Differential PositionVoltage request of 3609 * the mechanism. 3610 * </ul> 3611 * </ul> 3612 * 3613 * @param request Control object to request of the device 3614 * @return Status code of the request 3615 */ 3616 StatusCode setControl(Diff_VelocityVoltage_Position request); 3617 3618 /** 3619 * Differential control with Motion Magic® average target and position 3620 * difference target using voltage control. 3621 * <ul> 3622 * <li> <b>Diff_MotionMagicVoltage_Position Parameters:</b> 3623 * <ul> 3624 * <li> <b>AverageRequest:</b> Average MotionMagicVoltage request of the 3625 * mechanism. 3626 * <li> <b>DifferentialRequest:</b> Differential PositionVoltage request of 3627 * the mechanism. 3628 * </ul> 3629 * </ul> 3630 * 3631 * @param request Control object to request of the device 3632 * @return Status code of the request 3633 */ 3634 StatusCode setControl(Diff_MotionMagicVoltage_Position request); 3635 3636 /** 3637 * Differential control with Motion Magic® Expo average target and 3638 * position difference target using voltage control. 3639 * <ul> 3640 * <li> <b>Diff_MotionMagicExpoVoltage_Position Parameters:</b> 3641 * <ul> 3642 * <li> <b>AverageRequest:</b> Average MotionMagicExpoVoltage request of the 3643 * mechanism. 3644 * <li> <b>DifferentialRequest:</b> Differential PositionVoltage request of 3645 * the mechanism. 3646 * </ul> 3647 * </ul> 3648 * 3649 * @param request Control object to request of the device 3650 * @return Status code of the request 3651 */ 3652 StatusCode setControl(Diff_MotionMagicExpoVoltage_Position request); 3653 3654 /** 3655 * Differential control with Motion Magic® Velocity average target and 3656 * position difference target using voltage control. 3657 * <ul> 3658 * <li> <b>Diff_MotionMagicVelocityVoltage_Position Parameters:</b> 3659 * <ul> 3660 * <li> <b>AverageRequest:</b> Average MotionMagicVelocityVoltage request of 3661 * the mechanism. 3662 * <li> <b>DifferentialRequest:</b> Differential PositionVoltage request of 3663 * the mechanism. 3664 * </ul> 3665 * </ul> 3666 * 3667 * @param request Control object to request of the device 3668 * @return Status code of the request 3669 */ 3670 StatusCode setControl(Diff_MotionMagicVelocityVoltage_Position request); 3671 3672 /** 3673 * Differential control with voltage average target and velocity 3674 * difference target. 3675 * <ul> 3676 * <li> <b>Diff_VoltageOut_Velocity Parameters:</b> 3677 * <ul> 3678 * <li> <b>AverageRequest:</b> Average VoltageOut request of the mechanism. 3679 * <li> <b>DifferentialRequest:</b> Differential VelocityVoltage request of 3680 * the mechanism. 3681 * </ul> 3682 * </ul> 3683 * 3684 * @param request Control object to request of the device 3685 * @return Status code of the request 3686 */ 3687 StatusCode setControl(Diff_VoltageOut_Velocity request); 3688 3689 /** 3690 * Differential control with position average target and velocity 3691 * difference target using voltage control. 3692 * <ul> 3693 * <li> <b>Diff_PositionVoltage_Velocity Parameters:</b> 3694 * <ul> 3695 * <li> <b>AverageRequest:</b> Average PositionVoltage request of the 3696 * mechanism. 3697 * <li> <b>DifferentialRequest:</b> Differential VelocityVoltage request of 3698 * the mechanism. 3699 * </ul> 3700 * </ul> 3701 * 3702 * @param request Control object to request of the device 3703 * @return Status code of the request 3704 */ 3705 StatusCode setControl(Diff_PositionVoltage_Velocity request); 3706 3707 /** 3708 * Differential control with velocity average target and velocity 3709 * difference target using voltage control. 3710 * <ul> 3711 * <li> <b>Diff_VelocityVoltage_Velocity Parameters:</b> 3712 * <ul> 3713 * <li> <b>AverageRequest:</b> Average VelocityVoltage request of the 3714 * mechanism. 3715 * <li> <b>DifferentialRequest:</b> Differential VelocityVoltage request of 3716 * the mechanism. 3717 * </ul> 3718 * </ul> 3719 * 3720 * @param request Control object to request of the device 3721 * @return Status code of the request 3722 */ 3723 StatusCode setControl(Diff_VelocityVoltage_Velocity request); 3724 3725 /** 3726 * Differential control with Motion Magic® average target and velocity 3727 * difference target using voltage control. 3728 * <ul> 3729 * <li> <b>Diff_MotionMagicVoltage_Velocity Parameters:</b> 3730 * <ul> 3731 * <li> <b>AverageRequest:</b> Average MotionMagicVoltage request of the 3732 * mechanism. 3733 * <li> <b>DifferentialRequest:</b> Differential VelocityVoltage request of 3734 * the mechanism. 3735 * </ul> 3736 * </ul> 3737 * 3738 * @param request Control object to request of the device 3739 * @return Status code of the request 3740 */ 3741 StatusCode setControl(Diff_MotionMagicVoltage_Velocity request); 3742 3743 /** 3744 * Differential control with Motion Magic® Expo average target and 3745 * velocity difference target using voltage control. 3746 * <ul> 3747 * <li> <b>Diff_MotionMagicExpoVoltage_Velocity Parameters:</b> 3748 * <ul> 3749 * <li> <b>AverageRequest:</b> Average MotionMagicExpoVoltage request of the 3750 * mechanism. 3751 * <li> <b>DifferentialRequest:</b> Differential VelocityVoltage request of 3752 * the mechanism. 3753 * </ul> 3754 * </ul> 3755 * 3756 * @param request Control object to request of the device 3757 * @return Status code of the request 3758 */ 3759 StatusCode setControl(Diff_MotionMagicExpoVoltage_Velocity request); 3760 3761 /** 3762 * Differential control with Motion Magic® Velocity average target and 3763 * velocity difference target using voltage control. 3764 * <ul> 3765 * <li> <b>Diff_MotionMagicVelocityVoltage_Velocity Parameters:</b> 3766 * <ul> 3767 * <li> <b>AverageRequest:</b> Average MotionMagicVelocityVoltage request of 3768 * the mechanism. 3769 * <li> <b>DifferentialRequest:</b> Differential VelocityVoltage request of 3770 * the mechanism. 3771 * </ul> 3772 * </ul> 3773 * 3774 * @param request Control object to request of the device 3775 * @return Status code of the request 3776 */ 3777 StatusCode setControl(Diff_MotionMagicVelocityVoltage_Velocity request); 3778 3779 /** 3780 * Differential control with voltage average target and voltage 3781 * difference target. 3782 * <ul> 3783 * <li> <b>Diff_VoltageOut_Open Parameters:</b> 3784 * <ul> 3785 * <li> <b>AverageRequest:</b> Average VoltageOut request of the mechanism. 3786 * <li> <b>DifferentialRequest:</b> Differential VoltageOut request of the 3787 * mechanism. 3788 * </ul> 3789 * </ul> 3790 * 3791 * @param request Control object to request of the device 3792 * @return Status code of the request 3793 */ 3794 StatusCode setControl(Diff_VoltageOut_Open request); 3795 3796 /** 3797 * Differential control with position average target and voltage 3798 * difference target. 3799 * <ul> 3800 * <li> <b>Diff_PositionVoltage_Open Parameters:</b> 3801 * <ul> 3802 * <li> <b>AverageRequest:</b> Average PositionVoltage request of the 3803 * mechanism. 3804 * <li> <b>DifferentialRequest:</b> Differential VoltageOut request of the 3805 * mechanism. 3806 * </ul> 3807 * </ul> 3808 * 3809 * @param request Control object to request of the device 3810 * @return Status code of the request 3811 */ 3812 StatusCode setControl(Diff_PositionVoltage_Open request); 3813 3814 /** 3815 * Differential control with velocity average target and voltage 3816 * difference target. 3817 * <ul> 3818 * <li> <b>Diff_VelocityVoltage_Open Parameters:</b> 3819 * <ul> 3820 * <li> <b>AverageRequest:</b> Average VelocityVoltage request of the 3821 * mechanism. 3822 * <li> <b>DifferentialRequest:</b> Differential VoltageOut request of the 3823 * mechanism. 3824 * </ul> 3825 * </ul> 3826 * 3827 * @param request Control object to request of the device 3828 * @return Status code of the request 3829 */ 3830 StatusCode setControl(Diff_VelocityVoltage_Open request); 3831 3832 /** 3833 * Differential control with Motion Magic® average target and voltage 3834 * difference target. 3835 * <ul> 3836 * <li> <b>Diff_MotionMagicVoltage_Open Parameters:</b> 3837 * <ul> 3838 * <li> <b>AverageRequest:</b> Average MotionMagicVoltage request of the 3839 * mechanism. 3840 * <li> <b>DifferentialRequest:</b> Differential VoltageOut request of the 3841 * mechanism. 3842 * </ul> 3843 * </ul> 3844 * 3845 * @param request Control object to request of the device 3846 * @return Status code of the request 3847 */ 3848 StatusCode setControl(Diff_MotionMagicVoltage_Open request); 3849 3850 /** 3851 * Differential control with Motion Magic® Expo average target and 3852 * voltage difference target. 3853 * <ul> 3854 * <li> <b>Diff_MotionMagicExpoVoltage_Open Parameters:</b> 3855 * <ul> 3856 * <li> <b>AverageRequest:</b> Average MotionMagicExpoVoltage request of the 3857 * mechanism. 3858 * <li> <b>DifferentialRequest:</b> Differential VoltageOut request of the 3859 * mechanism. 3860 * </ul> 3861 * </ul> 3862 * 3863 * @param request Control object to request of the device 3864 * @return Status code of the request 3865 */ 3866 StatusCode setControl(Diff_MotionMagicExpoVoltage_Open request); 3867 3868 /** 3869 * Differential control with Motion Magic® Velocity average target and 3870 * voltage difference target. 3871 * <ul> 3872 * <li> <b>Diff_MotionMagicVelocityVoltage_Open Parameters:</b> 3873 * <ul> 3874 * <li> <b>AverageRequest:</b> Average MotionMagicVelocityVoltage request of 3875 * the mechanism. 3876 * <li> <b>DifferentialRequest:</b> Differential VoltageOut request of the 3877 * mechanism. 3878 * </ul> 3879 * </ul> 3880 * 3881 * @param request Control object to request of the device 3882 * @return Status code of the request 3883 */ 3884 StatusCode setControl(Diff_MotionMagicVelocityVoltage_Open request); 3885 3886 /** 3887 * Apply a generic empty control used to do nothing. 3888 * 3889 * @param request Control object to request of the device 3890 * @return Status code of the request 3891 */ 3892 StatusCode setControl(EmptyControl request); 3893 3894 /** 3895 * Control device with generic control request object. 3896 * <p> 3897 * User must make sure the specified object is castable to a valid control request, 3898 * otherwise this function will fail at run-time and return the NotSupported StatusCode 3899 * 3900 * @param request Control object to request of the device 3901 * @return Status code of the request 3902 */ 3903 StatusCode setControl(ControlRequest request); 3904 3905} 3906