public class DifferentialPositionDutyCycle : ControlRequest
type DifferentialPositionDutyCycle =
class
inherit ControlRequest
end
DifferentialPositionDutyCycle | Request PID to target position with a differential position setpoint. This control mode will set the motor's position setpoint to the position specified by the user. It will also set the motor's differential position setpoint to the specified position. TargetPosition Average position to drive toward in rotations. DifferentialPosition Differential position to drive toward in rotations. EnableFOC Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation. FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains. TargetSlot Select which gains are applied to the primary controller by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2]. DifferentialSlot Select which gains are applied to the differential controller by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2]. OverrideBrakeDurNeutral Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor. |
ConfigTimeout | The timeout when sending configs associated with this control |
ControlInfo |
Plain old data container holding name-value pairs of the control request parameters
(Inherited from ControlRequest) |
DifferentialPosition | Differential position to drive toward in rotations. |
DifferentialSlot | Select which gains are applied to the differential controller by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2]. |
EnableFOC | Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation. FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains. |
OverrideBrakeDurNeutral | Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor. |
TargetPosition | Average position to drive toward in rotations. |
TargetSlot | Select which gains are applied to the primary controller by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2]. |
UpdateFreqHz | The period at which this control will update at. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls. |
Equals | Determines whether the specified object is equal to the current object. (Inherited from Object) |
Finalize | Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object) |
ForceApplyConfigs | Forces configs to be applied the next time this is used in a setControl. This is not necessary in the majority of cases, because Phoenix will make sure configs are properly set when they are not already set |
GetHashCode | Serves as the default hash function. (Inherited from Object) |
GetType | Gets the Type of the current instance. (Inherited from Object) |
MemberwiseClone | Creates a shallow copy of the current Object. (Inherited from Object) |
SendRequest |
Sends this request out over CAN bus to the device
for the device to apply.
(Overrides ControlRequestSendRequest(String, UInt32, Boolean)) |
ToString |
Provides the string representation of this object
(Overrides ObjectToString) |
WithUpdateFreqHz | Sets the period at which this control will update at. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls. |