Class PositionTorqueCurrentFOC
Requires Phoenix Pro; Request PID to target position with torque current feedforward.
This control mode will set the motor's position setpoint to the position specified by the user. In addition, it will apply an additional torque current as an arbitrary feedforward value.public sealed class PositionTorqueCurrentFOC : ControlRequest, ICloneable
- Inheritance
-
PositionTorqueCurrentFOC
- Implements
- Inherited Members
Constructors
PositionTorqueCurrentFOC(double)
Requires Phoenix Pro; Request PID to target position with torque current feedforward.
This control mode will set the motor's position setpoint to the position specified by the user. In addition, it will apply an additional torque current as an arbitrary feedforward value. Position to drive toward in rotations.public PositionTorqueCurrentFOC(double Position)
Parameters
Positiondouble
Fields
FeedForward
Feedforward to apply in torque current in Amperes. This is added to the output of the onboard feedforward terms.
User can use motor's kT to scale Newton-meter to Amperes.- Units: A
public double FeedForward
Field Value
IgnoreHardwareLimits
Set to true to ignore hardware limit switches and the LimitForwardMotion and LimitReverseMotion parameters, instead allowing motion.
This can be useful on mechanisms such as an intake/feeder, where a limit switch stops motion while intaking but should be ignored when feeding to a shooter. The hardware limit faults and Forward/ReverseLimit signals will still report the values of the limit switches regardless of this parameter.public bool IgnoreHardwareLimits
Field Value
IgnoreSoftwareLimits
Set to true to ignore software limits, instead allowing motion.
This can be useful when calibrating the zero point of a mechanism such as an elevator. The software limit faults will still report the values of the software limits regardless of this parameter.public bool IgnoreSoftwareLimits
Field Value
LimitForwardMotion
Set to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.
public bool LimitForwardMotion
Field Value
LimitReverseMotion
Set to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.
public bool LimitReverseMotion
Field Value
OverrideCoastDurNeutral
Set to true to coast the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0A (zero torque).
public bool OverrideCoastDurNeutral
Field Value
Position
Position to drive toward in rotations.
- Units: rotations
public double Position
Field Value
Slot
Select which gains are applied by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2].
public int Slot
Field Value
UpdateFreqHz
The frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.
If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.public double UpdateFreqHz
Field Value
UseTimesync
Set to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). This eliminates the impact of nondeterministic network delays in exchange for a larger but deterministic control latency.
This requires setting the ControlTimesyncFreqHz config in MotorOutputConfigs. Additionally, when this is enabled, the UpdateFreqHz of this request should be set to 0 Hz.public bool UseTimesync
Field Value
Velocity
Velocity to drive toward in rotations per second. This is typically used for motion profiles generated by the robot program.
- Units: rotations per second
public double Velocity
Field Value
Properties
Name
Name of this control request.
public string Name { get; }
Property Value
Methods
Clone()
Creates a copy of this control request.
public PositionTorqueCurrentFOC Clone()
Returns
GetControlInfo()
Gets information about this control request.
public Dictionary<string, string> GetControlInfo()
Returns
- Dictionary<string, string>
Dictionary of control parameter names and corresponding applied values
SendRequest(string, uint)
Sends this request out over CAN bus to the device for the device to apply.
public StatusCode SendRequest(string network, uint deviceHash)
Parameters
Returns
- StatusCode
Status of the send operation
ToString()
Provides the string representation of this object.
public override string ToString()
Returns
WithFeedForward(double)
Modifies this Control Request's FeedForward parameter and returns itself for method-chaining and easier to use request API.
Feedforward to apply in torque current in Amperes. This is added to the output of the onboard feedforward terms. User can use motor's kT to scale Newton-meter to Amperes.- Units: A
public PositionTorqueCurrentFOC WithFeedForward(double newFeedForward)
Parameters
newFeedForwarddoubleParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithIgnoreHardwareLimits(bool)
Modifies this Control Request's IgnoreHardwareLimits parameter and returns itself for method-chaining and easier to use request API.
Set to true to ignore hardware limit switches and the LimitForwardMotion and LimitReverseMotion parameters, instead allowing motion. This can be useful on mechanisms such as an intake/feeder, where a limit switch stops motion while intaking but should be ignored when feeding to a shooter. The hardware limit faults and Forward/ReverseLimit signals will still report the values of the limit switches regardless of this parameter.public PositionTorqueCurrentFOC WithIgnoreHardwareLimits(bool newIgnoreHardwareLimits)
Parameters
newIgnoreHardwareLimitsboolParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithIgnoreSoftwareLimits(bool)
Modifies this Control Request's IgnoreSoftwareLimits parameter and returns itself for method-chaining and easier to use request API.
Set to true to ignore software limits, instead allowing motion. This can be useful when calibrating the zero point of a mechanism such as an elevator. The software limit faults will still report the values of the software limits regardless of this parameter.public PositionTorqueCurrentFOC WithIgnoreSoftwareLimits(bool newIgnoreSoftwareLimits)
Parameters
newIgnoreSoftwareLimitsboolParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithLimitForwardMotion(bool)
Modifies this Control Request's LimitForwardMotion parameter and returns itself for method-chaining and easier to use request API.
Set to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.public PositionTorqueCurrentFOC WithLimitForwardMotion(bool newLimitForwardMotion)
Parameters
newLimitForwardMotionboolParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithLimitReverseMotion(bool)
Modifies this Control Request's LimitReverseMotion parameter and returns itself for method-chaining and easier to use request API.
Set to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.public PositionTorqueCurrentFOC WithLimitReverseMotion(bool newLimitReverseMotion)
Parameters
newLimitReverseMotionboolParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithOverrideCoastDurNeutral(bool)
Modifies this Control Request's OverrideCoastDurNeutral parameter and returns itself for method-chaining and easier to use request API.
Set to true to coast the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0A (zero torque).public PositionTorqueCurrentFOC WithOverrideCoastDurNeutral(bool newOverrideCoastDurNeutral)
Parameters
newOverrideCoastDurNeutralboolParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithPosition(double)
Modifies this Control Request's Position parameter and returns itself for method-chaining and easier to use request API.
Position to drive toward in rotations.- Units: rotations
public PositionTorqueCurrentFOC WithPosition(double newPosition)
Parameters
newPositiondoubleParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithSlot(int)
Modifies this Control Request's Slot parameter and returns itself for method-chaining and easier to use request API.
Select which gains are applied by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2].public PositionTorqueCurrentFOC WithSlot(int newSlot)
Parameters
newSlotintParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithUpdateFreqHz(double)
Sets the frequency at which this control will update. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms). Some update frequencies are not supported and will be promoted up to the next highest supported frequency.
If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.public PositionTorqueCurrentFOC WithUpdateFreqHz(double newUpdateFreqHz)
Parameters
newUpdateFreqHzdoubleParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithUseTimesync(bool)
Modifies this Control Request's UseTimesync parameter and returns itself for method-chaining and easier to use request API.
Set to true to delay applying this control request until a timesync boundary (requires Phoenix Pro and CANivore). This eliminates the impact of nondeterministic network delays in exchange for a larger but deterministic control latency. This requires setting the ControlTimesyncFreqHz config in MotorOutputConfigs. Additionally, when this is enabled, the UpdateFreqHz of this request should be set to 0 Hz.public PositionTorqueCurrentFOC WithUseTimesync(bool newUseTimesync)
Parameters
newUseTimesyncboolParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself
WithVelocity(double)
Modifies this Control Request's Velocity parameter and returns itself for method-chaining and easier to use request API.
Velocity to drive toward in rotations per second. This is typically used for motion profiles generated by the robot program.- Units: rotations per second
public PositionTorqueCurrentFOC WithVelocity(double newVelocity)
Parameters
newVelocitydoubleParameter to modify
Returns
- PositionTorqueCurrentFOC
Itself