CTRE Phoenix 6 C++ 24.3.0
ctre::phoenix6::controls::VelocityVoltage Class Reference

Request PID to target velocity with voltage feedforward. More...

#include <ctre/phoenix6/controls/VelocityVoltage.hpp>

Inheritance diagram for ctre::phoenix6::controls::VelocityVoltage:
ctre::phoenix6::controls::ControlRequest

Public Member Functions

 VelocityVoltage (units::angular_velocity::turns_per_second_t Velocity, units::angular_acceleration::turns_per_second_squared_t Acceleration=0.0_tr_per_s_sq, bool EnableFOC=true, units::voltage::volt_t FeedForward=0.0_V, int Slot=0, bool OverrideBrakeDurNeutral=false, bool LimitForwardMotion=false, bool LimitReverseMotion=false)
 Request PID to target velocity with voltage feedforward. More...
 
VelocityVoltageWithVelocity (units::angular_velocity::turns_per_second_t newVelocity)
 Modifies this Control Request's Velocity parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithAcceleration (units::angular_acceleration::turns_per_second_squared_t newAcceleration)
 Modifies this Control Request's Acceleration parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithEnableFOC (bool newEnableFOC)
 Modifies this Control Request's EnableFOC parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithFeedForward (units::voltage::volt_t newFeedForward)
 Modifies this Control Request's FeedForward parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithSlot (int newSlot)
 Modifies this Control Request's Slot parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithOverrideBrakeDurNeutral (bool newOverrideBrakeDurNeutral)
 Modifies this Control Request's OverrideBrakeDurNeutral parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithLimitForwardMotion (bool newLimitForwardMotion)
 Modifies this Control Request's LimitForwardMotion parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithLimitReverseMotion (bool newLimitReverseMotion)
 Modifies this Control Request's LimitReverseMotion parameter and returns itself for method-chaining and easier to use request API. More...
 
VelocityVoltageWithUpdateFreqHz (units::frequency::hertz_t newUpdateFreqHz)
 Sets the period at which this control will update at. More...
 
std::string ToString () const override
 Returns a string representation of the object. More...
 
std::map< std::string, std::string > GetControlInfo () const override
 Gets information about this control request. More...
 
- Public Member Functions inherited from ctre::phoenix6::controls::ControlRequest
 ControlRequest (std::string name)
 Constructs a new Control Request with the given name. More...
 
std::string const & GetName () const
 
virtual std::map< std::string, std::string > GetControlInfo () const =0
 Gets information about this control request. More...
 
virtual ~ControlRequest ()=default
 
virtual std::string ToString () const =0
 

Public Attributes

units::angular_velocity::turns_per_second_t Velocity
 Velocity to drive toward in rotations per second. More...
 
units::angular_acceleration::turns_per_second_squared_t Acceleration
 Acceleration to drive toward in rotations per second squared. More...
 
bool EnableFOC
 Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. More...
 
units::voltage::volt_t FeedForward
 Feedforward to apply in volts. More...
 
int Slot
 Select which gains are applied by selecting the slot. More...
 
bool OverrideBrakeDurNeutral
 Set to true to static-brake the rotor when output is zero (or within deadband). More...
 
bool LimitForwardMotion
 Set to true to force forward limiting. More...
 
bool LimitReverseMotion
 Set to true to force reverse limiting. More...
 
units::frequency::hertz_t UpdateFreqHz {100_Hz}
 The period at which this control will update at. More...
 

Additional Inherited Members

- Protected Member Functions inherited from ctre::phoenix6::controls::ControlRequest
 ControlRequest (ControlRequest const &)=default
 
 ControlRequest (ControlRequest &&)=default
 
ControlRequestoperator= (ControlRequest const &)=default
 
ControlRequestoperator= (ControlRequest &&)=default
 
- Protected Attributes inherited from ctre::phoenix6::controls::ControlRequest
std::string name
 

Detailed Description

Request PID to target velocity with voltage feedforward.

This control mode will set the motor's velocity setpoint to the velocity specified by the user. In addition, it will apply an additional voltage as an arbitrary feedforward value.

Constructor & Destructor Documentation

◆ VelocityVoltage()

ctre::phoenix6::controls::VelocityVoltage::VelocityVoltage ( units::angular_velocity::turns_per_second_t  Velocity,
units::angular_acceleration::turns_per_second_squared_t  Acceleration = 0.0_tr_per_s_sq,
bool  EnableFOC = true,
units::voltage::volt_t  FeedForward = 0.0_V,
int  Slot = 0,
bool  OverrideBrakeDurNeutral = false,
bool  LimitForwardMotion = false,
bool  LimitReverseMotion = false 
)
inline

Request PID to target velocity with voltage feedforward.

This control mode will set the motor's velocity setpoint to the velocity specified by the user. In addition, it will apply an additional voltage as an arbitrary feedforward value.

Parameters
VelocityVelocity to drive toward in rotations per second.
AccelerationAcceleration to drive toward in rotations per second squared. This is typically used for motion profiles generated by the robot program.
EnableFOCSet to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation.

FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.

Parameters
FeedForwardFeedforward to apply in volts
SlotSelect which gains are applied by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2].
OverrideBrakeDurNeutralSet to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.
LimitForwardMotionSet to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.
LimitReverseMotionSet to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

Member Function Documentation

◆ GetControlInfo()

std::map< std::string, std::string > ctre::phoenix6::controls::VelocityVoltage::GetControlInfo ( ) const
inlineoverridevirtual

Gets information about this control request.

Returns
Map of control parameter names and corresponding applied values

Implements ctre::phoenix6::controls::ControlRequest.

◆ ToString()

std::string ctre::phoenix6::controls::VelocityVoltage::ToString ( ) const
inlineoverridevirtual

Returns a string representation of the object.

Returns
a string representation of the object.

Implements ctre::phoenix6::controls::ControlRequest.

◆ WithAcceleration()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithAcceleration ( units::angular_acceleration::turns_per_second_squared_t  newAcceleration)
inline

Modifies this Control Request's Acceleration parameter and returns itself for method-chaining and easier to use request API.

Acceleration to drive toward in rotations per second squared. This is typically used for motion profiles generated by the robot program.

Parameters
newAccelerationParameter to modify
Returns
Itself

◆ WithEnableFOC()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithEnableFOC ( bool  newEnableFOC)
inline

Modifies this Control Request's EnableFOC parameter and returns itself for method-chaining and easier to use request API.

Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation.

FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.

Parameters
newEnableFOCParameter to modify
Returns
Itself

◆ WithFeedForward()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithFeedForward ( units::voltage::volt_t  newFeedForward)
inline

Modifies this Control Request's FeedForward parameter and returns itself for method-chaining and easier to use request API.

Feedforward to apply in volts

Parameters
newFeedForwardParameter to modify
Returns
Itself

◆ WithLimitForwardMotion()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithLimitForwardMotion ( bool  newLimitForwardMotion)
inline

Modifies this Control Request's LimitForwardMotion parameter and returns itself for method-chaining and easier to use request API.

Set to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

Parameters
newLimitForwardMotionParameter to modify
Returns
Itself

◆ WithLimitReverseMotion()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithLimitReverseMotion ( bool  newLimitReverseMotion)
inline

Modifies this Control Request's LimitReverseMotion parameter and returns itself for method-chaining and easier to use request API.

Set to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

Parameters
newLimitReverseMotionParameter to modify
Returns
Itself

◆ WithOverrideBrakeDurNeutral()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithOverrideBrakeDurNeutral ( bool  newOverrideBrakeDurNeutral)
inline

Modifies this Control Request's OverrideBrakeDurNeutral parameter and returns itself for method-chaining and easier to use request API.

Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.

Parameters
newOverrideBrakeDurNeutralParameter to modify
Returns
Itself

◆ WithSlot()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithSlot ( int  newSlot)
inline

Modifies this Control Request's Slot parameter and returns itself for method-chaining and easier to use request API.

Select which gains are applied by selecting the slot. Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2].

Parameters
newSlotParameter to modify
Returns
Itself

◆ WithUpdateFreqHz()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithUpdateFreqHz ( units::frequency::hertz_t  newUpdateFreqHz)
inline

Sets the period at which this control will update at.

This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms).

If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

Parameters
newUpdateFreqHzParameter to modify
Returns
Itself

◆ WithVelocity()

VelocityVoltage & ctre::phoenix6::controls::VelocityVoltage::WithVelocity ( units::angular_velocity::turns_per_second_t  newVelocity)
inline

Modifies this Control Request's Velocity parameter and returns itself for method-chaining and easier to use request API.

Velocity to drive toward in rotations per second.

Parameters
newVelocityParameter to modify
Returns
Itself

Member Data Documentation

◆ Acceleration

units::angular_acceleration::turns_per_second_squared_t ctre::phoenix6::controls::VelocityVoltage::Acceleration

Acceleration to drive toward in rotations per second squared.

This is typically used for motion profiles generated by the robot program.

◆ EnableFOC

bool ctre::phoenix6::controls::VelocityVoltage::EnableFOC

Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%.

Set to false to use trapezoidal commutation.

FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.

◆ FeedForward

units::voltage::volt_t ctre::phoenix6::controls::VelocityVoltage::FeedForward

Feedforward to apply in volts.

◆ LimitForwardMotion

bool ctre::phoenix6::controls::VelocityVoltage::LimitForwardMotion

Set to true to force forward limiting.

This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

◆ LimitReverseMotion

bool ctre::phoenix6::controls::VelocityVoltage::LimitReverseMotion

Set to true to force reverse limiting.

This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

◆ OverrideBrakeDurNeutral

bool ctre::phoenix6::controls::VelocityVoltage::OverrideBrakeDurNeutral

Set to true to static-brake the rotor when output is zero (or within deadband).

Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.

◆ Slot

int ctre::phoenix6::controls::VelocityVoltage::Slot

Select which gains are applied by selecting the slot.

Use the configuration api to set the gain values for the selected slot before enabling this feature. Slot must be within [0,2].

◆ UpdateFreqHz

units::frequency::hertz_t ctre::phoenix6::controls::VelocityVoltage::UpdateFreqHz {100_Hz}

The period at which this control will update at.

This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms).

If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

◆ Velocity

units::angular_velocity::turns_per_second_t ctre::phoenix6::controls::VelocityVoltage::Velocity

Velocity to drive toward in rotations per second.


The documentation for this class was generated from the following file: