phoenix6.controls.duty_cycle_out#

Module Contents#

class phoenix6.controls.duty_cycle_out.DutyCycleOut(output: float, enable_foc: bool = True, override_brake_dur_neutral: bool = False, limit_forward_motion: bool = False, limit_reverse_motion: bool = False)#

Request a specified motor duty cycle.

This control mode will output a proportion of the supplied voltage which is supplied by the user.

Parameters:
  • output (float) – Proportion of supply voltage to apply in fractional units between -1 and +1

  • enable_foc (bool) –

    Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation.

    FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.

  • override_brake_dur_neutral (bool) – Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.

  • limit_forward_motion (bool) – Set to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

  • limit_reverse_motion (bool) – Set to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

property name: str#

Gets the name of this control request.

Returns:

Name of the control request

Return type:

str

property control_info: dict#

Gets information about this control request.

Returns:

Dictonary of control parameter names and corresponding applied values

Return type:

dict

output#

Proportion of supply voltage to apply in fractional units between -1 and +1

enable_foc#

Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation.

FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.

override_brake_dur_neutral#

Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.

limit_forward_motion#

Set to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

limit_reverse_motion#

Set to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

with_output(new_output: float) DutyCycleOut#

Modifies this Control Request’s output parameter and returns itself for method-chaining and easier to use request API.

Proportion of supply voltage to apply in fractional units between -1 and +1

Parameters:

new_output (float) – Parameter to modify

Returns:

Itself

Return type:

DutyCycleOut

with_enable_foc(new_enable_foc: bool) DutyCycleOut#

Modifies this Control Request’s enable_foc parameter and returns itself for method-chaining and easier to use request API.

Set to true to use FOC commutation (requires Phoenix Pro), which increases peak power by ~15%. Set to false to use trapezoidal commutation.

FOC improves motor performance by leveraging torque (current) control. However, this may be inconvenient for applications that require specifying duty cycle or voltage. CTR-Electronics has developed a hybrid method that combines the performances gains of FOC while still allowing applications to provide duty cycle or voltage demand. This not to be confused with simple sinusoidal control or phase voltage control which lacks the performance gains.

Parameters:

new_enable_foc (bool) – Parameter to modify

Returns:

Itself

Return type:

DutyCycleOut

with_override_brake_dur_neutral(new_override_brake_dur_neutral: bool) DutyCycleOut#

Modifies this Control Request’s override_brake_dur_neutral parameter and returns itself for method-chaining and easier to use request API.

Set to true to static-brake the rotor when output is zero (or within deadband). Set to false to use the NeutralMode configuration setting (default). This flag exists to provide the fundamental behavior of this control when output is zero, which is to provide 0V to the motor.

Parameters:

new_override_brake_dur_neutral (bool) – Parameter to modify

Returns:

Itself

Return type:

DutyCycleOut

with_limit_forward_motion(new_limit_forward_motion: bool) DutyCycleOut#

Modifies this Control Request’s limit_forward_motion parameter and returns itself for method-chaining and easier to use request API.

Set to true to force forward limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

Parameters:

new_limit_forward_motion (bool) – Parameter to modify

Returns:

Itself

Return type:

DutyCycleOut

with_limit_reverse_motion(new_limit_reverse_motion: bool) DutyCycleOut#

Modifies this Control Request’s limit_reverse_motion parameter and returns itself for method-chaining and easier to use request API.

Set to true to force reverse limiting. This allows users to use other limit switch sensors connected to robot controller. This also allows use of active sensors that require external power.

Parameters:

new_limit_reverse_motion (bool) – Parameter to modify

Returns:

Itself

Return type:

DutyCycleOut

with_update_freq_hz(new_update_freq_hz: phoenix6.units.hertz) DutyCycleOut#

Sets the period at which this control will update at. This is designated in Hertz, with a minimum of 20 Hz (every 50 ms) and a maximum of 1000 Hz (every 1 ms).

If this field is set to 0 Hz, the control request will be sent immediately as a one-shot frame. This may be useful for advanced applications that require outputs to be synchronized with data acquisition. In this case, we recommend not exceeding 50 ms between control calls.

Parameters:

new_update_freq_hz (hertz) – Parameter to modify

Returns:

Itself

Return type:

DutyCycleOut